• <pre id="2usos"><fieldset id="2usos"></fieldset></pre>
    參數(shù)資料
    型號: MIC3001GML TR
    廠商: Micrel Inc
    文件頁數(shù): 29/76頁
    文件大?。?/td> 0K
    描述: IC FOM MANAGEMENT W/CALIBR 24MLF
    標(biāo)準(zhǔn)包裝: 1,000
    類型: 收發(fā)器
    規(guī)程: SDHj Sonet
    電源電壓: 3 V ~ 3.6 V
    安裝類型: 表面貼裝
    封裝/外殼: 24-VFQFN 裸露焊盤,24-MLF?
    供應(yīng)商設(shè)備封裝: 24-MLF?(4x4)
    包裝: 帶卷 (TR)
    其它名稱: MIC3001GMLTR
    MIC3001GMLTR-ND
    Micrel, Inc.
    MIC3001
    August 2004
    35
    M9999-082404-A
    hbwhelp@micrel.com or (408) 955-1690
    Warm Resets
    The MIC3001 can be reset to its power-on default state
    during operation by setting the reset bit in OEMCFG0.
    When this bit is set, TXFAULT and RXLOS will be de-
    asserted, all registers will be restored to their normal
    power-on default values, and any A/D conversion in
    progress will be halted and the results discarded. The
    state
    of
    the
    MIC3001
    following
    this
    operation
    is
    indistinguishable from a power-on reset.
    Power-On Hour Meter
    The Power-On Hour meter logs operating hours using an
    internal real-time clock and stores the result in NVRAM.
    The hour count is incremented at ten-hour intervals in the
    middle of each interval. The first increment therefore
    takes
    place
    five
    hours
    after
    power-on.
    Time
    is
    accumulated whenever the MIC3001 is powered. The
    hour meter’s timebase is accurate to 5% over all MIC3001
    operating conditions. The counter is capable of storing
    counts of more than thirty years, but is ultimately limited
    by the write-cycle endurance of the non-volatile memory.
    This implies a range of at least twenty years. Actual results
    will depend on the operating conditions and write-cycle
    endurance of the part in question.
    Two registers, POHH and POHl, contain a 15-bit power-on
    hour measurement and an error flag, POHFLT. Great care
    has been taken to make the MIC3001’s hour meter immune
    to data corruption and to insure that valid data is maintained
    across power cycles. The hour meter employs multiple data
    copies and error correction codes to maintain data validity.
    This data is stored in the POHDATA registers. If POHFLT is
    set, however, the power-on hour meter data has been
    corrupted and should be ignored.
    It is recommended that a two-byte (or more) sequential read
    operation be performed on POHh and POHl to insure
    coherency between the two registers. These registers are
    accessible by the OEM using a valid OEM password. The
    only operation that should be performed on these registers
    is to clear the hour meters initial value, if necessary, at the
    time of product shipment. The hour meter result may be
    cleared by setting all eight POHDATA bytes to 00h.
    Power-On Hour Result Format
    High Byte, POHH
    Low Byte, POHI
    Error Flag
    Elapsed Time / 10 Hours, MSBs
    Elapsed Time / 10 Hours, LSBs
    MSB
    LSB
    Table 20. Power-On Hour Meter Result Format
    Test and Calibration Features
    Numerous features are included in the MIC3001 to
    facilitate development, testing, and diagnostics. These
    features are available via registers in the OEM area. As
    shown
    in
    Table
    21,
    these
    features
    include:
    Function
    Description
    Control
    Register(s)
    Analog loop-back
    Provides analog visibility of op-amp and DAC outputs via the ADC
    OEMCFG0
    Fault comparator disable control
    Disables the fault comparator
    OEMCAL0
    Fault comparator spin-on-channel mode
    Selects a single fault comparator channel
    OEMCAL0
    Fault comparator output read-back
    Allows host to read individual fault comparator outputs
    OEMRD
    RSOUT, /INT read-back
    Allows host to read the state of these pins
    OEMRD
    Inhibit EEPROM write cycles
    Speeds repetitive writes to registers backed up by NVRAM
    OEMCAL0
    APC calibration mode
    Allows direct writes to MODDAC and APCDAC (temperature
    compensation not used)
    OEMCAL0
    Continuity checking
    Forcing of RXLOS, TXFAULT, /INT
    OEMCAL0
    Halt A/D
    Stops A/D conversions; ADC in one-shot mode
    OEMCAL1
    ADC idle flag
    Indicates ADC status
    OEMCAL1
    A/D one-shot mode
    Performs a single A/D conversion on the selected input channel
    OEMCAL1
    A/D spin-on-channel mode
    Selects a single input channel
    OEMCAL1
    Channel selection
    Selects ADC or fault comparator channel for spin-on-channel modes
    OEMCAL1
    LUT index read-back
    Permits visibility of the LUT index calculated by the state-machine
    LUTINDX
    Manufacturer and device ID registers
    Facilitates presence detection and version control
    MFG_ID, DEV_ID
    Table 21. Test and Diagnostic Features
    相關(guān)PDF資料
    PDF描述
    IDT72235LB15TF IC FIFO 2048X18 SYNC 15NS 64TQFP
    IDT72235LB15PF IC FIFO 2048X18 SYNC 15NS 64TQFP
    LTC2865HDE#TRPBF IC TRANSCEIVER RS485 12-DFN
    LT1137ACG#TRPBF IC 3DRV/5RCV RS232 5V 28SSOP
    VI-26N-MX-F4 CONVERTER MOD DC/DC 18.5V 75W
    相關(guān)代理商/技術(shù)參數(shù)
    參數(shù)描述
    MIC3002 制造商:MICREL 制造商全稱:Micrel Semiconductor 功能描述:FOM Management IC with Internal Calibr ation
    MIC3002_10 制造商:MICREL 制造商全稱:Micrel Semiconductor 功能描述:FOM Management IC with Internal Calibration
    MIC-3002A 制造商:ADVANTECH 制造商全稱:Advantech Co., Ltd. 功能描述:4U CompactPCI Enclosure with 6-slot 3U Backplane
    MIC-3002A-6 制造商:ADVANTECH 制造商全稱:Advantech Co., Ltd. 功能描述:4U CompactPCI Enclosure with 6-slot 3U Backplane
    MIC-3002AD-6 制造商:ADVANTECH 制造商全稱:Advantech Co., Ltd. 功能描述:4U CompactPCI Enclosure with 6-slot 3U Backplane