![](http://datasheet.mmic.net.cn/370000/MC100EP40DTG_datasheet_16719551/MC100EP40DTG_4.png)
MC100EP40
http://onsemi.com
4
Table 4. 100EP DC CHARACTERISTICS, PECL
V
CC
= 3.3 V, V
EE
= 0 V (Note 2)
Symbol
Characteristic
40
°
C
25
°
C
85
°
C
Unit
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
I
EE
V
OH
V
OL
Power Supply Current
100
128
160
100
130
160
110
140
170
mA
Output HIGH Voltage (Note 3)
U, U, B, B
2225
2350
2475
2275
2400
2525
2300
2425
2550
mV
Output LOW Voltage (Note 3)
PLD
1775
1355
1900
1480
2025
1605
1800
1355
1925
1480
2050
1605
1825
1355
1950
1480
2075
1605
mV
V
IH
V
IL
V
BB
V
IHCMR
Input HIGH Voltage (Single
Ended)
2075
2420
2075
2420
2075
2420
mV
Input LOW Voltage (Single
Ended)
1355
1675
1355
1675
1355
1675
mV
Output Voltage Reference
1775
1875
1975
1775
1875
1975
1775
1875
1975
mV
Input HIGH Voltage Common Mode
Range (Differential Configuration) (Note 4)
2.0
3.3
2.0
3.3
2.0
3.3
V
I
IH
I
IL
Input HIGH Current
150
150
150
A
Input LOW Current
150
150
150
A
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
2. Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +0.3 V to
2.2 V.
3. All loading with 50 to V
CC
2.0 V.
4. V
IHCMR
min varies 1:1 with V
EE
, V
IHCMR
max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the most positive side of the differential
input signal.
Table 5. 100EP DC CHARACTERISTICS, PECL
V
CC
= 3.3 V, V
EE
= 0 V (Note 5)
Symbol
Characteristic
40
°
C
25
°
C
85
°
C
Unit
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
I
EE
V
OH
V
OL
Power Supply Current (Note 6)
100
128
160
100
130
160
110
140
170
mA
Output HIGH Voltage (Note 7)
3925
4050
4175
3975
4100
4225
4000
4125
4250
mV
Output LOW Voltage (Note 7)
U, U, B, B
PLD
3475
3055
3600
3180
3725
3305
3500
3055
3625
3180
3750
3305
3525
3055
3650
3180
3775
3305
mV
V
IH
V
IL
V
BB
V
IHCMR
Input HIGH Voltage (Single
Ended)
3775
4120
3775
4120
3775
4120
mV
Input LOW Voltage (Single
Ended)
3055
3375
3055
3375
3055
3375
mV
Output Voltage Reference
3475
3575
3675
3475
3575
3675
3475
3575
3675
mV
Input HIGH Voltage Common Mode
Range (Differential Configuration) (Note 8)
2.0
5.0
2.0
5.0
2.0
5.0
V
I
IH
I
IL
Input HIGH Current
150
150
150
A
Input LOW Current
150
150
150
A
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
5. Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +0.3 V to
2.2 V.
6. For (V
CC
V
EE
) > 3.3 V, 5 to 10 in line with V
EE
required for maximum thermal protection at elevated temperatures. Recommend
V
CC
V
EE
operation at
3.3 V.
7. All loading with 50 to V
CC
2.0 V.
8. V
IHCMR
min varies 1:1 with V
EE
, V
IHCMR
max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the most positive side of the differential
input signal.