MULTIJUNCTION TIMERS
10.7 TID (Input-related 16-bit Timer)
10.7.4 TID Counters (TID0CT, TID1CT, TID2CT)
s TID0 Counter (TID0CT)
<Address: H'0080 078C>
s TID1 Counter (TID1CT)
<Address: H'0080 0B8C>
s TID2 Counter (TID2CT)
<Address: H'0080 0C8C>
D0
12345
6
7
8
9
10
11
12
13
14
D15
TID0CT, TID1CT, TID2CT
<When reset : Indeterminate>
D
Bit Name
Function
R
W
0 - 15
TID0CT, TID1CT, TID2CT
16-bit counter value
Note: This register must always be accessed in halfwords.
The TID counters are a 16-bit up/down-counter. After the timer is enabled (by writing to the enable
bit in software), the counter starts counting synchronously with the count clock.