DAC Output Electrical Characteristics (Continued)
Unless otherwise noted: T
A = 25C, VCC = +5.0V, VIN = 0.7V, VABL =VCC,CL = 8 pF, Video Outputs = 2.0 VP-P. See (Note 7) for Min and Max parameters and
(Note 6) for Typicals. DAC parameters apply to all 4 DACs.
Symbol
Parameter
Conditions
Min
Typ
Max
Units
V
Max DAC
(Temp)
Variation in voltage of DAC with
temperature
0 < T < 70C ambient
±0.5
mV/C
V
Max DAC (VCC)
DAC output voltage variation with
V
CC
V
CC varied from 4.75V to 5.25V, DAC
register set to mid-range (0x7F)
50
mV
Linearity
Linearity of DAC over its range
5
%
Monotonicity
Monotonicity of the DAC
Excluding dead zones
±0.5
LSB
I
MAX
Max Load Current
1.0
mA
System Interface Signal Characteristics
Unless otherwise noted: T
A = 25C, VCC = +5.0V, VIN = 0.7V, VABL =VCC,CL = 8 pF, Video Outputs = 2.0 VP-P. See (Note 7) for Min and Max parameters and
(Note 6) for Typicals. DAC parameters apply to all 4 DACs.
Symbol
Parameter
Conditions
Min
Typ
Max
Units
V
VTH+
VFLYBACK positive switching
guarantee
Vertical Blanking triggered
2.0
V
SPOT
Spot Killer Voltage
CC Adjusted to Activate
3.4
3.9
4.3
V
Ref
V
Ref Output Voltage (pin 2)
1.25
1.45
1.65
V
IL (SCL, SDA)
Logic Low Input Voltage
0.5
1.5
V
IH (SCL, SDA)
Logic High Input Voltage
3.0
V
CC +
0.5
V
I
L (SCL, SDA)
Logic Low Input Current
SDA or SCL, Input Voltage = 0.4V
±10
A
I
H (SCL, SDA)
Logic High Input Voltage
SDA or SCL, Input Voltage = 4.5V
±10
A
V
OL (SCL, SDA)
Logic Low Output Voltage
I
O = 3 mA
0.5
V
f
H Min
Minimum Horizontal Frequency
PLL & OSD Operational; PLL Range
=0
25
kHz
f
H Max
Maximum Horizontal Frequency
PLL & OSD Operational; PLL Range
=3
110
kHz
I
HFB IN Max
Horizontal Flyback Input
Current Absolute Maximum During
Flyback
5mA
I
IN
Peak Current during flyback
Design Value
4
mA
I
HFB OUT Max
Horizontal Flyback Input Current
Absolute Maximum During Scan
700
A
I
OUT
Peak Current during Scan
Not exact - Duty Cycle Dependent
550
A
I
IN THRESHOLD
I
IN H-Blank Detection Threshold
0
A
t
H-BLANK ON
H-Blank Time Delay - On
+ Zero crossing of I
HFB to 50% of
output blanking start. I
24 = +1.5mA
45
ns
t
H-BLANK OFF
H-Blank Time Delay - Off
Zero crossing of I
HFB to 50% of
output blanking end. I
24 = 100A
85
ns
V
BLANK Max
Maximum Video Blanking Level
Test Setting 4, AC input signal
0
0.25
V
f
FREERUN
Free Run H Frequency, including
H Blank
42
kHz
t
PW CLAMP
Minimum Clamp Pulse Width
200
ns
V
CLAMP MAX
Maximum Low Level Clamp
Pulse Voltage
Video Clamp Functioning
2.0
V
CLAMP MIN
Minimum High Level Clamp
Pulse Voltage
Video Clamp Functioning
3.0
V
I
CLAMP Low
Clamp Gate Low Input Current
V
23 = 2V
0.4
A
I
CLAMP High
Clamp Gate High Input Current
V
23 = 3V
0.4
A
t
CLAMP-VIDEO
Time from End of Clamp Pulse to
Start of Video
Referenced to Blue, Red and Green
inputs
50
ns
LM1247
www.national.com
4