Static Electrical Characteristics - (Continued) 
V
BIAS   
(V
CC
, V
BS1,2,3
) = 15 V, V
SO1,2,3
 = V
SS 
 and T
A
 = 25 °C unless otherwise specified. The V
IN,
 V
TH
, and I
IN 
parameters 
are referenced to V
SS 
and are applicable to all six logic input leads: HIN1,2,3 & LIN1,2,3. The V
O   
and I
O
 parameters are 
referenced to V
SO1,2,3 
 and are applicable to the respective output leads: HO1,2,3 or LO1,2,3. 
www.irf.com
5
IRS2130/IRS21303/IRS2132 (J&S)PbF
Symbol 
Definition 
Min. Typ. Max. Units Test Conditions
I
SRC,AMP
Operational amplifier output source current 
4 
7 
— 
V
CA- 
= 0 V, V
SO  
=1 V
V
CAO 
= 4 V 
V
CA- 
= 1 V, V
SO  
=0 V
V
CAO 
= 2 V 
V
CA- 
= 0 V, V
SO  
=5 V
V
CAO 
= 0 V 
V
CA- 
= 5 V, V
SO  
=0 V
V
CAO 
= 5 V 
I
SNK,AMP
Operational amplifier output sink current 
1 
2.1 
— 
I
O+,AMP
Operational amplifier output high short circuit 
current 
Operational amplifier output low short circuit 
current 
— 
10 
— 
I
O-,AMP
— 
4 
— 
mA 
Dynamic Electrical Characteristics 
 V
BIAS   
(V
CC
, V
BS1,2,3
) = 15 V, V
SO1,2,3
 = V
SS
 , C
L
 = 1000 pF, T
A
 = 25 °C 
unless otherwise specified. 
Symbol 
Definition 
Min. Typ. Max. Units Test Conditions
t
on
t
off
t
t
f
t
itrip
t
bl
t
flt
t
flt, in
Turn-on propagation delay 
Turn-off propagation delay 
Turn-on rise time 
Turn-off fall time 
ITRIP to output shutdown propagation delay 
ITRIP blanking time 
ITRIP to FAULT indication delay 
400 
400 
— 
— 
400 
— 
350 
— 
500 
500 
80 
35 
660 
400 
550 
325 
700 
700 
125 
55 
920 
— 
870 
— 
r
V
S1,2,3 
= 0 V to 600 V
Input filter time (all six inputs) 
LIN1,2,3 to FAULT clear time IRS213(0,2) 
LIN1,2,3 & HIN1,2,3 to FAULT clear time 
IRS21303 
t
fltclr
5300 8500 13700 
IRS2130 
IRS213(2,03) 
1300 2000 3100
500 
700 1100
5 
10 
2.4 
3.2 
DT 
Deadtime 
ns 
SR+ 
SR- 
Operational amplifier slew rate (+) 
Operational amplifier slew rate (-) 
— 
— 
V/μs 
1 V input step 
NOTE:
 For high side PWM, HIN pulse width must be > 1.5 μs.
    PRELIMINARY