3
Absolute Maximum Ratings
Thermal Information
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +8.0V
Input or Output Voltage Applied. . . . . . . . . . GND -0.5 to V
CC
+0.5V
Operating Conditions
Voltage Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -4.75V to 5.25V
Temperature Range. . . . . . . . . . . . . . . . . . . . . . . . . . . 0
o
C to 70
o
C
Thermal Resistance (Typical, Note 1)
PDIP Package . . . . . . . . . . . . . . . . . . .
SOIC Package . . . . . . . . . . . . . . . . . . .
Maximum Junction Temperature . . . . . . . . . . . . . . . . . . . . . . .150
o
C
Maximum Storage Temperature Range. . . . . . . . . . -65
o
C to 150
o
C
Maximum Lead Temperature (Soldering 10s) . . . . . . . . . . . . .300
o
C
θ
JA
(
o
C/W)
67
77.0
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE:
1.
θ
JA
is measured with the component mounted on an evaluation PC board in free air.
DC Electrical Specifications
V
CC
= 5.0V
±
5%, T
A
= 0
o
C to 70
o
C
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
MAX
UNITS
Logical One Input Voltage
V
IH
V
CC
= 5.25V
2.0
-
V
Logical Zero Input Voltage
V
IL
V
CC
= 4.75V
-
0.8
V
Output HIGH Voltage
V
OH
I
OH
= -6.5mA, V
CC
- 4.75V
2.4
-
V
Output LOW Voltage
V
OL
I
OH
= +20.0mA, V
CC
= 4.75V
-
0.5
V
Input Leakage Current
I
I
V
IN
= V
CC
or GND, V
CC
= 5.25V
-10
-10
μ
A
Output Leakage Current
I
O
V
OUT
= V
CC
or GND, V
CC
= 5.25V
-10
-10
μ
A
Standby Power Supply Current
I
CCSB
V
IN
= V
CC
or GND, V
CC
= 5.25V Outputs Open
-
500
μ
A
Operating Power Supply Current
I
CCOP
f = 5.0MHz, V
IN
= V
CC
or GND, V
CC
= 5.25V, Outputs
Open (Note 2)
-
12
mA
Input Capacitance
CIN
FREQ = 1MHZ, V
CC
= Open, All Measurements are
Referenced to Device Ground
-
12
pF
Output Capacitance
CO
-
12
pF
AC Electrical Specifications
V
CC
= 5.0V
±
5%, T
A
= 0
o
C to 70
o
C (Note 3)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
MAX
UNITS
Clock to Data Out
t
PD
-
21
ns
Mux Select to Data Out
t
SELD
-
20
ns
Input Setup Time (DO-7/10-7)
t
S
10
-
ns
Input Hold Time (DO-7/10-7)
t
H
3
-
ns
Output Enable Time
t
ENA
-
20
ns
Output Disable Time
t
DIS
(Note 4)
-
13
ns
Clock Pulse Width
t
PW
10
-
ns
NOTES:
2. Power supply current is proportional to frequency. Typical rating for I
CCOP
is 2.4mA/MHz.
3. AC Testing is performed as follows: Input levels: 0V and 3.0V, timing reference levels = 1.5V, input rise and fall times driven at 1ns/V, output
load C
L
= 40pF.
4. Controlled by design or process parameters and not directly tested. Characterized upon initial design and after major design and/or process
changes.
HSP9520, HSP9521