DS26303: 3.3V, T1/E1/J1, Short-Haul, Octal Line Interface Unit 
46 of 97 
5.1.4 BERT Registers 
Register Name: 
Register Description: 
Register Address: 
Bit # 
Name 
PMUM 
Default 
Bit 7: Performance-Monitoring Update Mode (PMUM).
 When 0, a performance-monitoring update is initiated by 
the LPMU register bit. When 1, a performance-monitoring update is initiated by the receive performance-monitoring 
update signal (RPMU). Note: If RPMU or LPMU is 1, changing the state of this bit may cause a performance-
monitoring update to occur. 
BCR 
BERT Control Register 
00h 
7 
6 
5 
4 
3 
2 
1 
0 
LPMU 
0 
RNPL 
0 
RPIC 
0 
MPR 
0 
APRD 
0 
TNPL 
0 
TPIC 
0 
0 
Bit 6: Local Performance-Monitoring Update (LPMU).
 This bit causes a performance-monitoring update to be 
initiated if the local performance-monitoring update is enabled (PMUM = 0). A 0-to-1 transition causes the 
performance-monitoring registers to be updated with the latest data, and the counters reset (0 or 1). For a second 
performance-monitoring update to be initiated, this bit must be set to 0, and back to 1. If LPMU goes low before the 
PMS bit goes high, an update might not be performed. This bit has no affect when PMUM = 1. 
Bit 5: Receive New Pattern Load (RNPL).
 A 0-to-1 transition of this bit causes the programmed test pattern 
(QRSS, PTS, PLF[4:0], PTF[4:0], and BSP[31:0]) to be loaded in to the receive pattern generator. This bit must be 
changed to 0 and back to 1 for another pattern to be loaded. Loading a new pattern forces the receive pattern 
generator out of the sync state, which causes a resynchronization to be initiated. Note: QRSS, PTS, PLF[4:0}, 
PTF[4:0], and BSP[31:0] must not change from the time this bit transitions from 0 to 1 until four RXCK clock cycles 
after this bit transitions from 0 to 1. 
Bit 4: Receive Pattern Inversion Control (RPIC).
 When 0, the receive incoming data stream is not altered. When 
1, the receive incoming data stream is inverted. 
Bit 3: Manual Pattern Resynchronization (MPR).
 A 0-to-1 transition of this bit causes the receive pattern 
generator to resynchronize to the incoming pattern. This bit must be changed to 0 and back to 1 for another 
resynchronization to be initiated. Note: A manual resynchronization forces the receive pattern generator out of the 
sync state. 
Bit 2: Automatic Pattern Resynchronization Disable (APRD). 
When 0, the receive pattern generator 
automatically resynchronizes to the incoming pattern if six or more times during the current 64-bit window the 
incoming data stream bit and the receive pattern generator output bit did not match. When 1, the receive pattern 
generator does not automatically resynchronize to the incoming pattern. Note: Automatic synchronization is 
prevented by not allowing the receive pattern generator to automatically exit the sync state. 
Bit 1: Transmit New Pattern Load (TNPL). 
A 0-to-1 transition of this bit causes the programmed test pattern 
(QRSS, PTS, PLF[4:0], PTF[4:0], and BSP[31:0]) to be loaded in to the transmit pattern generator. This bit must be 
changed to zero and back to one for another pattern to be loaded. Note: QRSS, PTS, PLF[4:0}, PTF[4:0], and 
BSP[31:0] must not change from the time this bit transitions from 0 to 1 until four TXCK clock cycles after this bit 
transitions from 0 to 1. 
Bit 0: Transmit Pattern Inversion Control (TPIC). 
When 0, the transmit outgoing data stream is not altered. 
When 1, the transmit outgoing data stream is inverted.