2
DOT75 SERIES
OUTPUT SPECIFICATIONS
(Note 1)
PARAMETER
Efficiency
CONDITIONS/DESCRIPTION
Nominal input, full rated load.
MIN
NOM
MAX
78
82
85
87
+1
UNITS
3.3V output
5V output
12V output
15V output
%
Set Point Accuracy
Minimum Loads
Ripple and Noise
Nominal input, full rated load.
-1
0
%
Amps
Full load, 20MHz bandwidth.
3.3V output
5V output
12V output
15V output
75
75
100
100
75
0
mV
PP
Output Power
Overshoot / Undershoot
Load Regulation
Transient Response
Turn-On Rise Time
NOTES:
1
)
All parameters measured at Tc=25°C, nominal input voltage and full rated load unless otherwise noted. Refer to the Power-One Reference Guide for the definition of terms, measurement
circuits and other information.
Derate for 3.3V output.
Output voltage overshoot/undershoot at turn-on/turn-off.
Changes in load starting at 50% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load change, 3% max. deviation.
Time required for output voltage to rise from 10% to 90%.
Watts
V
%
mS
mS
0.1
1
10
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
Overvoltage Protection
CONDITIONS/DESCRIPTION
MIN
4.1
6.0
14
17
NOM
MAX
4.2
6.4
16
19
UNITS
3.3V output
5V output
12V output
15V output
V
Overload Protection
Overtemperature Protection
Remote Sense
Output Trim
Inhibit
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
Total voltage compensation for cable losses with respect to the main output.
Adjustment range.
TTL compatible logic signal will inhibit outputs by the application of a low signal. An open circuit or external TTL high signal allows normal operation.
250
+10
mV
%
-40
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
Agency Approvals
CONDITIONS/DESCRIPTION
UL1950, CSA 22.2 No. 234/950, EN60950 (TüV)
Input to output, 24V models.
Input to output, 48V models.
MIN
NOM
MAX
UNITS
Pending
Dielectric Withstand Voltage
700
1544
VDC
Leakage Current
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
Input Transient Protection
10
m
A
Class
kV
V/M
FCC CFR title 47 Part 15 Sub-Part J - Conducted, EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per IEEE-C62.41-1980.
Meets ETSI 300 132.
Input to output.
B
8
10
24V models
48V models
50
100
V
Insulation Resistance
10
M
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
Altitude
CONDITIONS/DESCRIPTION
Operating.
Non-operating.
At 100% load, case temperature.
MIN
NOM
MAX
10k
40k
100
105
UNITS
ASL Ft.
ASL Ft.
°C
°C
°C/Watt
Operating Temperature
Storage Temperature
Case Thermal Impedance
-40
-55
The case thermal impedance is specified as the case temperature rise
over ambient per watt of internally dissipated power.
0°C to 70°C (after 15 minute warm-up).
Non-condensing.
9
Temperature Coefficient
Relative Humidity
Shock
Vibration
MTBF
Unit Weight
DOT SERIES APPLICATION NOTES: Remote ON/OFF Operation
The remote ON/OFF pin may be left floating if this function is not used. It is recommended to drive this pin with TTL com-
patible circuitry. When the ON/OFF pin is pulled low with respect to the -INPUT, the converter is placed in a low power drain state. The input capacitors are kept fully charged in the OFF mode. For
proper operation, this input may be driven from a logic gate directly. The ON/OFF pin should never be pulled more than 0.3 volts below -INPUT or have a voltage greater than +6 volts applied.
±0.02
±0.05
95
20
6
%/°C
%RH
G
G
RMS
Hours
oz/gm
5
Calculated.
1,000,000
3.5/99
Advanced Product
Release