參數(shù)資料
型號: DEMOMPR083
廠商: Freescale Semiconductor
文件頁數(shù): 14/35頁
文件大?。?/td> 0K
描述: BOARD DEMO FOR MPR083 CTLR
產品培訓模塊: Sensor Toolbox
標準包裝: 1
傳感器類型: 觸摸,電容式
傳感范圍: 8 個按鈕/鍵
接口: I²C
電源電壓: 1.8 V ~ 3.6 V
嵌入式: 是,MCU,8 位
已供物品: 板,電池
已用 IC / 零件: MPR083
產品目錄頁面: 2808 (CN2011-ZH PDF)
相關產品: MPR083EJR2CT-ND - IC CTLR TOUCH SENSR PROX 16TSSOP
MPR083QR2-ND - IC CTLR TOUCH SENSOR PROX 16-QFN
MPR083Q-ND - IC CTLR TOUCH SENSOR PROX 16-QFN
MPR083EJR2TR-ND - IC CTLR TOUCH SENSR PROX 16TSSOP
MPR083EJ-ND - IC CTLR TOUCH SENSR PROX 16TSSOP
MPR083
Sensors
Freescale Semiconductor
21
8Calibration
8.1
Introduction
The MPR083 is self-calibrating. This is done both at initial start-up of the device and during run time.
8.2
Initial Start-up Conditions
Initial calibration of the MPR083 occurs every time the device resets. The first key detection cycle is used as a baseline
capacitance value for all remaining calculations. Thus, a touch is detected by taking the difference between this baseline value
and the current capacitance on the electrode.
8.3
Auto-Calibration
The MPR083 has an auto-calibration feature. This is enabled through the Rotary Configuration Register (Section 3.4), by setting
the ACE bit high. Auto calibration is done by two mechanisms. The basic auto-calibration will recalculate the baseline value after
6 sample periods. Thus the auto calibrate period can be calculate by multiplying the master clock period (in milliseconds) and the
touch acquisition sample period with a factor of 64.
Equation 6
If a touch is currently being detected the auto-calibration will not engage and calibration will be ignored. The device can also be
calibrated when a key is being touched, this is controlled by stuck key detection.
8.4
Stuck Key Detection
The Stuck Key Detection system allows the application to specify the maximum amount of time a touch should be detected before
it is calibrated into the baseline and the touch is ignored. This is controlled by setting the Stuck Key Timeout multiplication factor
(SKT). The timeout period can be calculated by multiplying the SKT, master clock period (in ms) and touch acquisition sample
period with a factor of 64.
Equation 7
When Stuck Key Detection is off a touched key will remain touched indefinitely and never be calibrated into the baseline value.
8.4.1
Stuck Key Timeout Register
The Stuck Key Timeout Register is used to determine the electrode scan period of the system. The I2C slave address of the Stuck
Key Timeout Register is 0x09.
Figure 25. Stuck Key Timeout Register
7
6
543210
R
SKT
W
Reset:
0
000000
= Unimplemented
Table 15. Stuck Key Timeout Register Field Descriptions
Field
Description
7:0
SKT
Stuck Key Timeout – The Stuck Key Timeout field selects or reports the
multiplication factor that is used to determine how often electrodes are calibrated
while a touch is being detected.
00000000 Encoding 0 – Turns off Stuck Key Detection
00000001 Encoding 1 – Sets the SKT multiplication factor to 2
~
11111111 Encoding 255 – Sets the SKT multiplication factor to 256
AutoCalibrationPeriod ms
MCP
TASP
64
=
AutoCalibrationPeriod ms
MCPTASPSKT
64
=
相關PDF資料
PDF描述
0210390880 CABLE JUMPER 1MM .076M 19POS
EEM28DTBI CONN EDGECARD 56POS R/A .156 SLD
ADR02ARZ-REEL IC VREF SERIES PREC 5V 8-SOIC
EA-OEM-410 KIT LPC3250 259 WITH QVGA
VI-J7P-EZ CONVERTER MOD DC/DC 13.8V 25W
相關代理商/技術參數(shù)
參數(shù)描述
DEMO-MSA 制造商:Avago Technologies 功能描述:DEMOBOARD MSA-XX05,10,11,36,70,86 - Bulk
DEMONB5CP1V1 制造商:OMRON AUTOMATION AND SAFETY 功能描述:NB5 CP1 PLC SALES DEMO
DEMO-NB5CP1V1 制造商:OMRON AUTOMATION AND SAFETY 功能描述:NB5 CP1 PLC SALES DEMO 制造商:OMRON INDUSTRIAL AUTOMATION 功能描述:NB5 CP1 PLC Sales Demo
DEMO-NB7CP1V1 制造商:OMRON INDUSTRIAL AUTOMATION 功能描述:NB7 CP1 PLC Sales Demo
DEMO-NJ51-KIT-ECT-0-V1 制造商:OMRON INDUSTRIAL AUTOMATION 功能描述:NJ5 Demo UGKIT, TJG5ML2 to NJE