CYM8210BPM
Document #: 38-05008 Rev. **
Page 3 of 8
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature
–
55
°
C to +125
°
C
Ambient Temperature with
Power Applied
–
10
°
C to +85
°
C
Supply Voltage to Ground Potential
–
0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State
–
0.5V to +7.0V
DC Input Voltage
–
0.5V to +7.0V
Operating Range
Range
Ambient
Temperature
0
°
C to +70
°
C
V
CC
Commercial
5V
±
10%
Electrical Characteristics
Over the Operating Range
Parameter
Description
Test Conditions
CYM8210-70
Min.
Max.
Unit
V
OH
V
OL
V
IH
V
IL
I
IX
I
OZ
Output HIGH Voltage
V
CC
= Min., I
OH
=
–
1.0 mA
V
CC
= Min., I
OL
= 2.1 mA
2.4
V
Output LOW Voltage
0.4
V
Input HIGH Voltage
2.2
V
CC
0.8
V
Input LOW Voltage
–
0.3
V
Input Leakage Current
GND < V
I
< V
CC
GND < V
O
< V
CC
,
Output Disabled
–
10
+10
μ
A
μ
A
Output Leakage
Current
–
10
+10
I
CC
V
CC
Operating
Supply Current
V
CC
= Max., I
OUT
= 0 mA,
CS < V
IL
Max. V
CC
, CS > V
IH
,
Min. Duty Cycle = 100%
158
mA
I
SB1
Automatic CS Power-
Down Current
[1]
120
mA
I
SB2
Automatic CS Power-
Down Current
[1]
Max. V
CC
, CS > V
CC
- 0.2V,
V
IN
> V
CC
–
0.2V,
or V
IN
< 0.2V
150
μ
A
Capacitance
[
2
]
Parameter
C
IN
C
OUT
Description
Test Conditions
T
A
= 25
°
C, f = 1 MHz,
V
CC
= 5.0V
Max.
60
50
Unit
pF
pF
Input Capacitance
Output Capacitance
AC Test Loads and Waveforms
Notes:
1.
2.
A pull-up resistor to V
on the E3/E2/E1/E0 input is required to keep the device deselected during V
CC
power-up, otherwise I
SB
will exceed values given.
Tested on a sample basis.
8210
–
4
8210
–
5
90%
10%
3.0V
GND
90%
10%
ALL INPUT PULSES
5V
OUTPUT
30 pF
INCLUDING
JIG AND
SCOPE
5V
OUTPUT
5 pF
INCLUDING
JIG AND
SCOPE
(a)
(b)
< 5 ns
< 5 ns
OUTPUT
R1481
R1481
R2
255
R2
255
167
Equivalent to:
TH
é
VENIN EQUIVALENT
1.73V