4-99
Setting the Control Register
The following will illustrate a counter write and subsequent
reads that places stable, accurate values on the data bus
from the counter-timer.
The counter is addressed and the required values are
loaded with a write operation. The control register is
addressed next and loaded with B9H.
The counter will now decrement with each input clock pulse
while the gate is valid. Assuming the counter has not decre-
mented to zero and its value is to be read without affecting
the counter’s operation, a write to the control register is per-
formed. 78H is loaded into the control register.
The counter is addressed and read operations are per-
formed.
Function Pin Description
DB7 - DB0
- 8-bit bidirectional bus used to transfer binary
information between the microprocessor and the dual
counter-timer.
V
DD
, V
SS
- Power and ground for device.
A0, A1, and A2
- Addresses used to select counters or reg-
isters.
TPB/WR, RD
- Directional signals that determine whether
data will be placed on the bus from a counter or the interrupt
status register (RD active) (memory mapped), or data on the
bus will be placed into a counter or control register (TPB/WR
active). The following connections are required between the
microprocessor and the counter-timer in the CDP1800-
series input/output mapping mode.
During an output instruction, data from the memory is
strobed into the counter-timer during TPB when RD is active,
and latched on TPB’s trailing edge. Data is read from the
counter-timer when RD is not active between the trailing
edges of TPA and TPB. See Figures 11, 12, and 13.
TACL, TBCL
- Clocks used to decrement the counter.
TAG, TBG
- Gate inputs used to control counter.
TAO, TAO
- Complemented outputs of Timer A.
TBO, TBO
- Complemented outputs of Timer B.
INT
- Common interrupt output. Active when counter decre-
ments to zero.
RESET
- Active low signal that resets counter outputs (TAO,
TBO low, TAO, TBO high). The interrupt output is set high
and the status register is cleared.
IO/MEM
- Tied high in CDP1800-series input/output mode,
otherwise tied low.
TPA
- Tied to TPA of the CDP1800-series microprocessors.
During memory mapping, it is used to latch the high order
address bit for the chip select. In the CDP1800 input/output
mode, it is used to gate the N lines. When the counter-timer
is used with other microprocessors, or when the high order
address of the CDP1800-series microprocessors is exter-
nally latched, it is connected to V
DD
.
CS
- An active high signal that enables the device.
1
0
1
1
1
0
0
1
POSITIVE GATE ENABLING
REQUIRED
MODE 1 SELECTED
LOAD COUNTER
WITH JAM REGISTER
HOLDING REGISTER
CONTINUOUSLY
UPDATED BY COUNTER
COUNTER START
INTERRUPT OUTPUT
ENABLED
CONTROL
REGISTER = B9H
BUS 7
BUS 0
FIGURE 6.
0
1
1
1
1
0
0
0
COUNTER OUTPUTS
UNAFFECTED
COUNTER VALUE
UNAFFECTED
FREEZE HOLDING
REGISTER
UNCHANGED
CONTROL
REGISTER = 78H
BUS 7
BUS 0
FIGURE 7.
MICROPROCESSOR
MRD
TPB
TPA
N Lines
COUNTER-TIMER
RD
TPB/WR
TPA
Address Lines
and IO/MEM to V
DD
CDP1878C