DC Electrical Characteristics
CD4006BC (Note 2) (Continued)
Symbol
Parameter
Conditions
b
40
§
C
a
25
§
C
a
85
§
C
Units
Min
Max
Min
Typ
Max
Min
Max
V
IL
Low Level
Input Voltage
V
DD
e
5.0V, V
O
e
0.5V or 4.5V
V
DD
e
10V, V
O
e
1.0V or 9.0V
V
DD
e
15V, V
O
e
1.5V or 13.5V
1.5
3.0
4.0
2.25
4.5
6.75
1.5
3.0
4.0
1.5
3.0
4.0
V
V
V
V
IH
High Level
Input Voltage
V
DD
e
5.0V, V
O
e
0.5V or 4.5V
V
DD
e
10V, V
O
e
1.0V or 9.0V
V
DD
e
15V, V
O
e
1.5V or 13.5V
3.5
7.0
11
3.5
7.0
11
2.75
5.5
8.25
3.5
7.0
11
V
V
V
I
OL
Low Level
Output Current
(Note 3)
V
DD
e
5.0V, V
O
e
0.4V
V
DD
e
10V, V
O
e
0.5V
V
DD
e
15V, V
O
e
1.5V
0.52
1.3
3.6
0.44
1.1
3.0
0.88
2.25
8.8
0.36
0.9
2.4
mA
mA
mA
I
OH
High Level
Output Current
(Note 3)
V
IL
e
0V, V
IH
e
V
DD
V
DD
e
5.0V, V
O
e
4.6V
V
DD
e
10V, V
O
e
9.5V
V
DD
e
15V, V
O
e
13.5V
b
0.52
b
1.3
b
3.6
b
0.44
b
1.1
b
3.0
b
0.88
b
2.25
b
8.8
b
0.36
b
0.9
b
2.4
mA
mA
mA
I
IN
Input Current
V
DD
e
15V, V
IN
e
0V
V
DD
e
15V, V
IN
e
15V
b
0.3
0.3
b
10
b
5
10
b
5
b
0.3
0.3
b
1.0
1.0
m
A
m
A
AC Electrical Characteristics
*
CD4006BM/CD4006BC T
A
e
25
§
C, C
L
e
50 pF, unless otherwise noted
Symbol
Parameter
Conditions
Min
Typ
Max
Units
t
PLH
, t
PHL
Propagation Delay Time (t
PLH
e
t
PHL
)
V
DD
e
5.0V
V
DD
e
10V
V
DD
e
15V
200
100
80
400
200
150
ns
ns
ns
t
TLH
, t
THL
Transition Time (t
TLH
e
t
THL
)
V
DD
e
5.0V
V
DD
e
10V
V
DD
e
15V
100
50
40
200
100
80
ns
ns
ns
t
WL
, t
WH
Minimum Clock Pulse Width (t
WL
e
t
WH
)
V
DD
e
5.0V
V
DD
e
10V
V
DD
e
15V
100
45
35
200
100
70
ns
ns
ns
t
RCL
, t
FCL
Clock Rise and Fall Time (t
RCL
e
t
FCL
)
V
DD
e
5.0V
V
DD
e
10V
V
DD
e
15V
15
15
15
m
s
m
s
m
s
t
SU
Minimum Set-Up Time
V
DD
e
5.0V
V
DD
e
10V
V
DD
e
15V
50
25
20
100
50
40
ns
ns
ns
t
H
Minimum Hold Time
V
DD
e
5.0V
V
DD
e
10V
V
DD
e
15V
55
35
30
110
70
60
ns
ns
ns
f
CL
Maximum Clock Frequency
V
DD
e
5.0V
V
DD
e
10V
V
DD
e
15V
2.5
5.0
7.0
5.0
12
16
MHz
MHz
MHz
C
L
Input Capacitance
Data Input
CLK Input
5.0
7.5
pF
pF
*
AC Parameters are guaranteed by DC correlated testing.
Note 1:
‘‘Absolute Maximum Ratings’’ are those values beyond which the safety of the device cannot be guaranteed; they are not meant to imply that the devices
should be operated at these limits. The tables of ‘‘Recommended Operating Conditions’’ and ‘‘Electrical Characteristics’’ provide conditions for actual device
operation.
Note 2:
V
SS
e
0V unless otherwise specified.
Note 3:
I
OL
and I
OH
are tested one output at a time.
3