ASAHI KASEI 
[AK4707] 
MS0551-E-00 
2006/10 
- 26 - 
6.
Control Interface 
I
2
C-bus Control Mode 
1. WRITE Operations 
Figure 7 shows the data transfer sequence in I
2
C-bus mode. All commands are preceded by a START condition. A HIGH 
to LOW transition on the SDA line while SCL is HIGH indicates a START condition (Figure 13). After the START 
condition, a slave address is sent. This address is 7bits long followed by an eighth bit that is a data direction bit (R/W). 
The most significant seven bits of the slave address are fixed as “0010001”. If the slave address match that of the 
AK4707, the AK4707 generates the acknowledge and the operation is executed. The master must generate the 
acknowledge-related clock pulse and release the SDA line (HIGH) during the acknowledge clock pulse (Figure 15). A 
“1” for R/W bit indicates that the read operation is to be executed. A “0” indicates that the write operation is to be 
executed. The second byte consists of the address for control registers of the AK4707. The format is MSB first, and those 
most significant 3-bits are fixed to zeros (Figure 9). The data after the second byte contain control data. The format is 
MSB first, 8bits (Figure 10). The AK4707 generates an acknowledge after each byte has been received. A data transfer is 
always terminated by a STOP condition generated by the master. A LOW to HIGH transition on the SDA line while SCL 
is HIGH defines a STOP condition (Figure 13). 
The AK4707 can execute multiple one byte write operations in a sequence. After receipt of the third byte, the AK4707 
generates an acknowledge, and awaits the next data again. The master can transmit more than one byte instead of 
terminating the write cycle after the first data byte is transferred. After the receipt of each data, the internal address 
counter is incremented by one, and the next data is taken into next address automatically. If the address exceeds 09H prior 
to generating the stop condition, the address counter will “roll over” to 00H and the previous data will be overwritten. 
The data on the SDA line must be stable during the HIGH period of the clock. The HIGH or LOW state of the data line 
can only change when the clock signal on the SCL line is LOW (Figure 15) except for the START and the STOP 
condition. 
S
T
A
R
T
Slave
Address
Address(n)
SDA
A
C
K
A
C
K
S
A
C
K
Sub
Data(n)
P
S
T
O
P
Data(n+x)
A
C
K
Data(n+1)
A
C
K
R/W= “0”
A
C
K
Figure 7. Data transfer sequence at the I
2
C-bus mode 
0 
0 
1 
0 
0 
0 
1 
R/W 
Figure 8. The first byte 
0 
0 
0 
A4 
A3 
A2 
A1 
A0 
Figure 9. The second byte 
D7 
D6 
D5 
D4 
D3 
D2 
D1 
D0 
Figure 10. Byte structure after the second byte