Two-Wire Chopper-Stabilized Hall Effect Latch
A1242
3
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
DEVICE QUALIFICATION PROGRAM
Contact Allegro for information.
EMC (Electromagnetic Compatibility) PERFORMANCE
Contact Allegro for information.
ELECTRICAL CHARACTERISTICS over full operating voltage and temperature ranges, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min.   Typ.
1
Max.  Units
Electrical Characteristics
Supply Voltage
2
3
V
CC
Operating, T
J
< 165癈
3.5        24    V
Supply Current
I
CC(L)
-I1, B < B
RP
5
    6.9    mA
-I2, B < B
RP
2
5    mA
I
CC(H)
-I1 and -I2, B > B
OP
12        17    mA
Output Slew Rate
4
dI/dt    R
S
= 100 ? C
S
= 20 pF, no bypass capacitor
    36       mA/約
Chopping Frequency
f
C
    200        kHz
Power-On Time
t
PO
V
CC
> V
CC(MIN)
    25    約
Power-On State
5
POS   t
PO
< t
PO(max)
, dV
CC
/ dt > 25 mV / 約
   I
CC(H)
Supply Zener Clamp Voltage
V
Z(supply)
I
CC
= 20 mA; T
A
= 25癈
28    
    V
Supply Zener Current
6
I
Z(supply)
V
S
= 28 V
    20    mA
Reverse Battery Current
I
RCC
V
RCC
= 18 V
    2.5    mA
Magnetic Characteristics
7
Operate Point
B
OP
South pole adjacent to branded face of device
5    32    80    G
Release Point
B
RP
North pole adjacent to branded face of device
80   32    5    G
Hysteresis
B
HYS
B
OP
B
RP
40    64    110    G
1
Typical values are at T
A
= 25癈 and V
CC
= 12 V. Performance may vary for individual units, within the specified maximum and mini-
mum limits.
2
Maximum voltage must be adjusted for power dissipation and junction temperature; see Power Derating section.
3
V
CC
represents the generated voltage between the V
CC
pin and the GND pin.
4
The value of dI is the difference between 90% of I
CC(H)
and 10% of I
CC(L)
, and the value of dt is time period between those two
points. The value of dI/dt depends on the value of the bypass capacitor, if one is used, with greater capacitances resulting in lower
rates of change.
5
For t > t
PO(max)
, and B
RP
< B < B
OP
, POS is undefined.
6
Maximum current limit is equal to the maximum I
CCL(max)
+ 3 mA.
7
Magnetic flux density, B, is indicated as a negative value for north-polarity magnetic fields, and as a positive value for south-polarity
magnetic fields. This so-called algebraic convention supports arithmetic comparison of north and south polarity values, where the rela-
tive strength of the field is indicated by the absolute value of B, and the sign indicates the polarity of the field (for example, a 100 G
field and a 100 G field have equivalent strength, but opposite polarity).