參數(shù)資料
型號(hào): 81030
廠商: Desco
文件頁(yè)數(shù): 2/8頁(yè)
文件大?。?/td> 0K
描述: FINISH FLOOR STATFREE 55GAL
標(biāo)準(zhǔn)包裝: 1
系列: Statfree™
處理劑/清潔劑類型: 抗靜電地板涂層
使用: 地板
技術(shù)規(guī)格: 10&sup7; ~ 10&sup9;表面電阻系數(shù)
數(shù)量: 55 加侖
包裝:
No Sealer Application: Sealing is recommended for
increasing coverage and correcting problem concrete
surfaces that are not dry or free from grease, oil, etc. If the
subfloor surface is dry, level, and free from dirt, grease, oil,
paint, sealer, old adhesives, and other foreign materials it
may be suitable to applying Statfree finish directly onto the
concrete.
COvERAGE
Desco Statfree Dissipative Floor Finish covers
approximately 2000 square feet per gallon per coat on
smooth surfaces. Coverage is less on coarse or textured
surfaces. With 18% solids, Statfree Floor Finish is easier
to apply with significantly better productivity than competing
brands.
DRY TIME
It is recommended that Statfree be allowed to dry to the
touch. At higher relative humidity levels, a longer drying
time may be necessary. Do not use force air drying. Wait
6 hours before allowing light traffic, 12 hours before regular
traffic, 48 hours before any wet maintenance, and 72 hours
before heavy equipment and floor truck traffic.
CLOSE CONTAINER AFTER EACH USE. KEEP FROM
FREEZING. DO NOT TAKE INTERNALLY.
Floor Stripping
Figure 3. Statguard Floor Stripper Item No. 10442,
5 gallon container
Stripping the floor is recommended for first time application
of any finish. New tiles are supplied with a protective
factory finish that protects during installation but should be
stripped away prior to any floor finish application. Properly
maintained floors should be stripped one to three times
annually, depending on traffic and buildup of contaminated
finish. Statguard Floor Stripper is recommended to strip
multiple layers of floor finish or coatings.
Equipment needed:
Push broom
Single pad 175 RPM stripping machine
(with black or brown stripping pad)
Mops
Statguard Stripper, Item #10441
Buckets
Wet vacuum
TB-2045 Page 2 of 8
Floor Preparation - Surface
CONCRETE
Two measures are used to determine a good concrete
surface for Statfree
Floor Finish:
1. The surface should be sealed.
2. The surface should be cleaned of all contaminants.
SURFACE
Surface to be finished should be clean, dry, and smooth.
Heavy dirt or grease build up should be removed with a
stripper or degreaser. DO NOT use Statfree on surfaces
colder than 45° F.
SEALING
Surface preparation is absolutely critical for porous
materials such as concrete. Proper preparation simplifies
application, increases durability and ensures proper
performance. Industrial grade polyurethane, vinyl or acrylic
base sealers are recommended to seal highly porous floors
before the application of Statfree Floor Finish. Enamel
sealers can be used for bare wood, while enamel undercoat
with rust inhibitors are recommended for metal surfaces.
DO NOT use Statfree on surfaces colder than 45° F.
New concrete should be allowed to cure for 60 days before
sealing. Concrete surfaces do not all have the same
physical and chemical properties. They vary widely due to
the variety of ways concrete can be formulated, poured or
finished.
There are several methods to prepare problem concrete.
Each method depends on the condition of the concrete.
Cleaning methods range from: sweeping, vacuuming, wire
brush, air-blasting, water jet, steam cleaning, or stripping.
Concrete surfaces are very porous and should be properly
sealed prior to the application of Statfree Floor Finish.
Adhesion properties for the concrete sealer can be
increased by profiling or rouging the concrete surface
through acid etching, rotary drum sanding, scarifying or
mechanically scratching the surface. The concrete sealer
will reduce the porosity of the concrete and provide a
smooth level surface for the finish. The sealer also provides
a barrier to prevent any water migrating up through the
surface of the concrete.
DESCO WEST
- 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178 Fax (909) 627-7449
DESCO EAST
- One Colgate Way, Canton, MA 02021-1407 (781) 821-8370 Fax (781) 575-0172 Web Site: Desco.com
Figure 2. Foot grounders should be used on ESD protective
flooring
2010 DESCO INDUSTRIES INC.
Employee Owned
相關(guān)PDF資料
PDF描述
82064 VINYL ANTIFATIG GRY .375 36X60'
82068 RUBBER BLACK G2E4 .060 48X40'
82082 MAT STATFREE AFR RUBBER
82101 DISPOSABLE ESD MAT 14X22
8212 TABLE MAT ESD BEIGE 2X4'
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
810300-0017 制造商:Seastrom Mfg 功能描述:
8103-0106-40 功能描述:EMI 墊圈與接地墊 RoHS:否 制造商:Gore 長(zhǎng)度:8 mm 寬度:2.5 mm 厚度:2.4 mm 產(chǎn)品類型:Pads
810-30-13 制造商:未知廠家 制造商全稱:未知廠家 功能描述:KUGELROLLE ROBUST D 30.0MM
81031 制造商:Brady Corporation 功能描述:
8103-1 制造商:Amphenol RF 功能描述: 制造商:DAGE 功能描述: 制造商:TE Connectivity 功能描述: