Philips Semiconductors
Product specification
74F1763
Intelligent DRAM controller (IDC)
1999 Jan 08
6
ABSOLUTE MAXIMUM RATINGS
Operation beyond the limits set forth in this table may impair the useful life of the device. Unless otherwise noted, these limits are over the
operating free-air temperature range.
SYMBOL
PARAMETER
V
CC
Supply voltage
V
IN
Input voltage
I
IN
Input current
V
OUT
Voltage applied to output in High output state
I
OUT
Current applied to output in Low output state
T
A
Operating free-air temperature range
T
STG
Storage temperature
RATING
–0.5 to +7.0
–0.5 to +7.0
–30 to +5
–0.5 to +V
CC
120
0 to +70
–65 to +150
UNIT
V
V
mA
V
mA
C
C
RECOMMENDED OPERATION CONDITIONS
SYMBOL
PARAMETER
LIMITS
NOM
5.0
UNIT
MIN
4.5
2.0
MAX
5.5
V
CC
V
IH
V
IL
I
IK
I
OH
I
OL
T
A
Supply voltage
High-level input voltage
Low-level input voltage
Input clamp current
High-level output current
1
Low-level output current
1
Operating free-air temperature range
V
V
V
0.8
–18
–15
24
70
mA
mA
mA
C
0
NOTE:
1. Transient currents will exceed these values in actual operation.
DC ELECTRICAL CHARACTERISTICS
Over recommended operating free-air temperature range unless otherwise noted.
SYMBOL
PARAMETER
TEST CONDITIONS
1
LIMITS
UNIT
MIN
TYP
2
MAX
V
CC
= MIN,
V
IL
= MAX,
V
IH
= MIN
I
OH
= –15 mA
10% V
CC
5% V
CC
5% V
CC
10% V
CC
5% V
CC
5% V
CC
2.5
V
V
OH
High-level output voltage
2.7
3.4
V
I
OH23
= –35 mA
2.4
V
V
CC
= MIN,
V
IL
= MAX,
V
IH
= MIN
OL
I
= 24 mA
0.35
0.50
V
V
OL
Low-level output voltage
0.35
0.50
V
I
OL24
= 60 mA
0.35
0.80
V
V
IK
I
I
I
IH
I
IL
I
OS
I
CC
Input clamp voltage
V
CC
= MIN, I
I
= I
IK
V
CC
= 0.0V, V
I
= 7.0V
V
CC
= MAX, V
I
= 2.7V
V
CC
= MAX, V
I
= 0.5V
V
CC
= MAX, V
O
= 2.25V
V
CC
= MAX
–0.73
–1.2
V
Input current at maximum input voltage
100
A
High-level input current
20
A
Low-level input current
–0.6
mA
Output current
5
–100
–225
mA
Supply current (total)
220
mA
NOTES:
1. For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions for the applicable type.
2. All typical values are at V
= 5V, T
= 25 C.
3. I
OH2
is transient current necessary to guarantee a Low to High transition in a 70 transmission line.
4. I
is transient current necessary to guarantee a High to Low transition in a 70 transmission line.
5. Not more than one output should be shorted at a time. For testing I
, the use of high-speed test apparatus and/or sample-and-hold
techniques are preferable in order to minimize internal heating and more accurately reflect operational values. Otherwise, prolonged
shorting of a High output may raise the chip temperature well above normal and thereby cause invalid readings in other parameter tests. In
any sequence of parameter tests, I
OS
tests should be performed last.