![](http://datasheet.mmic.net.cn/230000/700FS-Y2DA40_datasheet_15556350/700FS-Y2DA40_6.png)
6
700
–
FS Electronic High Performance Timing Relays
Specifications, Continued
Outputs
Contact type
Switching capacity
Relay as changeover switch
Voltage: 440 VAC
according to IEC 947-5-1:
3 A/440 VAC (inductive load, AC 14)
1 A/24 VDC (inductive load, DC 13)
according to UL 508:
1.5 A/250 VAC (B300)
10 A gL (Fast Blow Fuse)
mechanical:
30 Ml. of operations
electrical operations:
4 Ml. at 1 A/250 VAC, cos = 1
1.5 Ml. at 1 A/250 VAC, cos = 0.3
0.5 Ml. at 6 A/24 VDC, resistive
2 Ml. at 0.2 A/230 VDC, resistive
1 Ml. at 0.2 A/110 VDC, L/R = 20 ms
1 LED, combination signal
5% of full scale
Current I
th
: 8 A
Power: 2000 VA
3 A/250 VAC (inductive load, AC 15)
3 A/120 VAC (B300)
Short-circuit protection
Life
0.2 Ml. at 6 A/250 VAC, cos = 1
0.3 Ml. at 3 A/250 VAC, cos = 0.3
2 Ml. at 4 A/24 VDC, resistive
1 Ml. at 0.4 A/24 VDC, L/R = 20 ms
1 Ml. at 0.1 A/230 VDC, L/R = 20 ms
State indicator
Setting accuracy
General Data
Insulation characteristics
2 kVAC/50 Hz test voltage according to VDE 0435
and 6 kV 1.2/50 s surge voltage according to IEC 947-1 between all inputs and outputs
Performance of following requirements:
Surge capacity of the supply voltage according to IEC 1000-4-5: 4 kV 1.2/50 s
Burst according to IEC 1000-4-4: 6 kV 6/50 ns
ESD discharge according to IEC 1000-4-2: Contact 8 kV, air 8 kV
Electromagnetical HF field according to IEC 801-3 and conducted electromagnetical HF signal according
to IEC 801-6: Level 3
Electromagnetical fields according to EN 55 022: class B
according to VDE 106, part 101
56 Cycles (24 h) at 25...40
°
C and 95% rel. humdity according to IEC 68-2-30 and IEC 68-2-3
4 g in 3 axis at 10...500 Hz, test FC according to IEC 68-2-6
50 g according to IEC 68-2-27
Enclosure: IP 40
IP 30 (Single-function)
Termnal:
IP 20 according to IEC 947-1
100 g
UL, C-UL, Germanischer Lloyd, CE Certified
Open:
–25
°
C ... +60
°
C
Enclosed:
–25
°
C ... +45
°
C
Storage:
–40
°
C ... +85
°
C
Screw termnal M3.5 for Posidrive Number.2, Philips and slotted screws Number.2. suitable for power screwdriver.
Rated tightening torque 8.8 LB–IN 0.8 Nm(max. 1.2 Nm
Dual-chamber systemfor termnal cross-sections of 1 x 0.5 mm
2
... 2 x 2.5 mm
2
(solid) or stranded 2 x 2.5 mm
2
(flexible with sleeve), AWG 20 to 14.
Finger protection according to VDE 0106
Front mounting; For snap-on mounting on DIN rail 35 mmor screw fixing by adapter and 2 screws M4
Synthetic material without dioxin according to EC/EFTA notification Number. 93/0141/D – electrical contacts with
cadmum
EMC/Interference immunity
EMC/Emssion
Safe isolation
Climatic withstand
Vibration resistance
Shock resistance
Protection class
Weight
Approval
Ambient temperature
Termnals
Mounting
Disposal