![](http://datasheet.mmic.net.cn/230000/700FS-Y2DA40_datasheet_15556350/700FS-Y2DA40_3.png)
3
700
–
FS Electronic High Performance Timing Relays
Technical Data
700
–
FSM Multi
–
Function High Performance Timing Relays
Description
SPDT
DPDT
Multi-function timng relays 700-FSM3U includes 10 setting functions:
(A)
- On-delay
(B)
- Off-delay
(C)
- On- and off-delay
(D)
- One shot
(E)
- Fleeting off-delay
(F)
- Flasher (repeat cycle starts w/pulse)
(I)
- On-delay pulse generator
(L)
- Pulse converter
(On)
- ON-Function *
(Off)
- OFF-Function *
* (for installation and maintenance)
Up
Down
700–FSM4
0
0
0
0
0.8
1.0
A
Multi-time setting range 0.05 s...60 h
(1s)
(3s)
(10s)
(1mn)
(3mn)
(10mn)
(1h)
(3h)
(10h)
(60h)
0.05...1 s
0.15...3 s
0.5...10 s
0.05...1 mn
0.15...3 mn
0.5...10 mn
0.05...1 h
0.15...3 h
0.5...10 h
3...60 h
10h
NOTE:
Switch
is on DPDT relays only.
When switch is down, one contact is
instantaneous and one is timed. When
switch is up, both contacts are timed.
Supply voltages (A1/A2)
Cat. No.
Cat. No.
U23
24...48 VDC; 24...240 VAC, 50/60 Hz
700-FSM3UU23
700-FSM4UU23
Z12
12 VDC
700-FSM3UZ12
700-FSM4UZ12
700
–
FS Single Function High Performance Timing Relays
Description
SPDT
DPDT
Supply voltages (A1/A2)
12 VDC
24...48 VDC
24...240 VAC, 50/60 Hz
Z12
U23
0
0
0
0
0.8
1.0
22.5 mmTimng
Relays
available mono-time ranges
Complete the Cat. No. with the cor-
responding identification
the table on the next page.
from
NOTE: Only the 700–FSA and
700–FSB are available with the “U”
multi–time setting ranges (0.05s to
60h).
Multi-time setting ranges
0.05 s...60 h
0.05...1 s
0.15...3 s
(10s)
0.5...10 s
(1mn)
0.05...1 mn
(3mn)
0.15...3 mn
(10mn)
0.5...10 mn
(1h)
0.05...1 h
(3h)
0.15...3 h
(10h)
0.5...10 h
(60h)
3...60 h
(1s)
(3s)
10h
See 700–FS Timing Charts
Cat. No.
Cat. No.
(A) On-delay
The output contact changes state after the time delay is completed.
700–FSA3CU23
700–FSA3FU23
700–FSA3UU23
700–FSA3 Z12
700–FSA3 U23
700-FSB3CU23
700-FSB3FU23
700-FSB3UU23
700-FSB3 Z12
700-FSB3 U23
700-FSA4UU23
700-FSA4UZ12
(B) Off-delay
Input power must be supplied to termnal (A1/A2) continuously. The output contact
changes state when switch “S” is closed. When switch “S” is opened, the time delay
begins. After the time delay is completed, the contact returns to shelf state.
700-FSB4UU23
700-FSB4UZ12
(C) On- and off-delay
Input power must be supplied to termnal (A1/A2) continuously. The output contact
changes state when switch “S” is closed and the time delay complete. When switch
“S” is opened, the time delay begins again. After the time delay is completed, the
contact returns to shelf state.
700-FSC3KU23
700-FSC3LU23
700-FSC3 Z12
700-FSC3 U23
—
(D) One shot
The output contact changes state when the relay is energized. The output contact
returns to shelf state when the time delay is completed.
700-FSD3KU23
700-FSD3LU23
700-FSD3 Z12
700-FSD3 U23
700-FSE3KU23
700-FSE3LU23
700-FSE3 Z12
700-FSE3 U23
—
(E) Fleeting off-delay
(Min. Pulse AC 50ms
–
DC 30ms)
Input power must be supplied to termnal (A1/A2) continuously. The output contact
changes state after closing and opening switch “S”. After the time delay is completed,
the contact returns to shelf state.
(F) Flasher (Repeat Cycle Starting with Pulse)
The output contact changes state when power is applied. At the end of the time
delay, the output contact returns to shelf state. This cycle continues until the power is
removed.
—
700-FSF3KU23
700-FSF3LU23
700-FSF3 Z12
700-FSF3 U23
—