9
Z86C27/C97
CPS DC-2974-04
AC CHARACTERISTICS
Unique to Z86C97, T
A
=0
°
C to +70
°
C; V
CC
=+4.5 V to +5.5 V; F
OSC
= 4 MHz
No
Symbol
Parameter
Min
Max
Unit
Notes
1
2
3
4
TdA(AS)
TdAS(AS)
TdAS(DR)
TwAS
Address Valid to /AS High Delay
/AS High to Address Float Delay
/AS High to Read Data Required Valid
/AS Low Width
35
45
ns
ns
ns
ns
[2]
[2]
[1,2]
[2]
250
55
5
6
7
8
TdAZ(DS)
TwDSR
TwDSW
TdDSR(DR)
Address Float to /DS Low
/DS (Read) Low Width
DS (Write) Low Width
/DS Low to Read Data Required Valid
0
ns
ns
ns
ns
[2]
[1,2]
[1,2]
[1,2]
185
110
130
9
10
11
12
ThDR(DS)
TdDS(A)
TdDS(AS)
TdR/W(AS)
Read Data to /DS High Hold
/DS High to Address Active Delay
/DS High to /AS Low Delay
R//W Valid to /AS High Delay
5
ns
ns
ns
ns
55
55
35
[2]
[2]
[2]
13
14
15
TdDS(R/W)
TdDW(DSW)
TdDS(DW)
/DS High to R//W Not Valid
Write Data Valid to /DS Low Delay
/DS High to Write Data Not Valid
55
35
55
ns
ns
ns
[2]
[2]
[2]
16
17
18
TdA(DR)
TdAS(DS)
TdDI(DS)
Address Valid to Read Data Required Valid
/AS High to /DS Low Delay
Data Input Setup to /DS High
330
ns
ns
ns
[1,2]
[2]
[1]
65
75
Notes:
[1] When using extended memory timing, for parameters 3, 6, 7, 8, and 16, add 2 TpC (250 ns @ 4.0 MHz).
[2] Min and Max times are in nanoseconds unless otherwise noted.
1993 by Zilog, Inc. All rights reserved. No part of this document
may be copied or reproduced in any form or by any means
without the prior written consent of Zilog, Inc. The information in
this document is subject to change without notice. Devices sold
by Zilog, Inc. are covered by warranty and patent indemnification
provisions appearing in Zilog, Inc. Terms and Conditions of Sale
only. Zilog, Inc. makes no warranty, express, statutory, implied or
by description, regarding the information set forth herein or
regarding the freedom of the described devices from intellectual
property infringement. Zilog, Inc. makes no warranty of mer-
chantability or fitness for any purpose. Zilog, Inc. shall not be
responsible for any errors that may appear in this document.
Zilog, Inc. makes no commitment to update or keep current the
information contained in this document.
Zilog's products are not authorized for use as critical compo-
nents in life support devices or systems unless a specific written
agreement pertaining to such intended use is executed between
the customer and Zilog prior to use. Life support devices or
systems are those which are intended for surgical implantation
into the body, or which sustains life whose failure to perform,
when properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result in
significant injury to the user.
Zilog, Inc. 210 East Hacienda Ave.
Campbell, CA 95008-6600
Telephone (408) 370-8000
Telex 910-338-7621
FAX 408 370-8056