VS-550 Voltage Controlled SAW Oscillator
Vectron International, 267 Lowell Rd, Hudson NH 03051-4916
Tel: 1-88-VECTRON-1 Website: www.vectron.com
Page 4 of 7
Rev: 25Apr05
Absolute Maximum Ratings
Parameter
Symbol
V
CC
I
IN
I
OUT
V
C
T
STR
T
PEAK
/ t
P
Ratings
0 to 6
100
25
0 to V
CC
-55 to 125
260 / 40
Unit
V
mA
mA
V
°
C
°
C / sec
Power Supply
Input Current
Output Current
Voltage Control Range
Storage Temperature
Solder Temperature / Duration
Stresses in excess of the absolute maximum ratings can permanently damage the device. Also, exposure to
these absolute maximum ratings for extended periods may adversely affect device reliability. Functional
operation is not implied at these or any other conditions in excess of those represented in the operational
sections of this datasheet. Permanent damage is also possible if any device input (Vc or FS) draws greater
than 100mA.
Suggested Output Load Configurations
LV-PECL to LV-PECL:
For short transmission lengths, the
power
consumption could be reduced by removing the 100
resistor and
doubling the value of the pull down resistors.
Functional Test:
Allows standard power supply configuration.
Since AC coupled, the LV-PECL levels cannot be measured.
LV-PECL to LVDS:
Restricted for short transmission lengths.
Configuration may require modification depending on LVDS receiver.
40
40
150
150
49
49
+3.3V
Production Test:
Allows direct DC coupling into 50
measurement
equipment. Must bias the power supplies as shown. Similar to Figure 1.
0.01
μ
F
0.01
μ
F
1
6
2
3
4
5
Vc
FS
Gnd
+3.3V
0.01
μ
F
0.10
μ
F
Vcc
COutput
240
Output
240
100
Z = 50
Z = 50
Output
Gnd
3
4
Z = 50
+3.3V
0.10
μ
F
FS
Vc
6
1
2
5
COutput
Vcc
0.01
μ
F
Z = 50
Gnd
FS
Vc
4
3
Output
240
1
6
2
5
COutput
Vcc
0.01
μ
F
+3.3V
0.10
μ
F
240
-1.3V
FS
Vc
3
4
6
1
2
5
COutput
Output
Vcc
+2.0V
0.01
μ
F
0.10
μ
F