www.ti.com
ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
TIMING REQUIREMENTS
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
SN74ALVCH16501
18-BIT UNIVERSAL BUS TRANSCEIVER
WITH 3-STATE OUTPUTS
SCES024J–JULY 1995–REVISED OCTOBER 2004
PARAMETER
TEST CONDITIONS
V
CC
MIN TYP
(1)
V
CC
- 0.2
1.2
2
1.7
2.2
2.4
2
MAX
UNIT
I
OH
= -100
μ
A
I
OH
= -4 mA
I
OH
= -6 mA
1.65 V to 3.6 V
1.65 V
2.3 V
2.3 V
2.7 V
3 V
3 V
1.65 V to 3.6 V
1.65 V
2.3 V
2.3 V
2.7 V
3 V
3.6 V
1.65 V
1.65 V
2.3 V
2.3 V
3 V
3 V
3.6 V
3.6 V
3.6 V
3 V to 3.6 V
3.3 V
3.3 V
V
OH
V
I
OH
= -12 mA
I
OH
= -24 mA
I
OL
= 100
μ
A
I
OL
= 4 mA
I
OL
= 6 mA
0.2
0.45
0.4
0.7
0.4
0.55
±
5
V
OL
V
I
OL
= 12 mA
I
OL
= 24 mA
V
I
= V
CC
or GND
V
I
= 0.58 V
V
I
= 1.07 V
V
I
= 0.7 V
V
I
= 1.7 V
V
I
= 0.8 V
V
I
= 2 V
V
I
= 0 V to 3.6 V
(2)
V
O
= V
CC
or GND
V
I
= V
CC
or GND,
One input at V
CC
- 0.6 V,
I
I
μ
A
25
-25
45
-45
75
-75
I
I(hold)
μ
A
±
500
±
10
40
750
I
OZ(3)
I
CC
I
CC
C
i
C
io
μ
A
μ
A
μ
A
pF
pF
I
O
= 0
Other inputs at V
CC
or GND
Control inputs V
I
= V
CC
or GND
A or B ports
V
O
= V
CC
or GND
4
8
(1)
(2)
All typical values are at V
= 3.3 V, T
= 25
°
C.
This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to
another.
For I/O ports, the parameter I
OZ
includes the input leakage current.
(3)
V
CC
= 2.5 V
±
0.2 V
MIN
V
CC
= 3.3 V
±
0.3 V
MIN
V
CC
= 2.7 V
UNIT
MAX
150
MIN
MAX
150
MAX
150
f
clock
Clock frequency
MHz
LE high
CLK high or low
Data before CLK
↑
3.3
3.3
2.2
1.9
1.3
0.6
1.4
3.3
3.3
2.1
1.6
1.1
0.6
1.7
3.3
3.3
1.7
1.5
t
w
Pulse duration
ns
t
su
Setup time
CLK high
CLK low
ns
Data before LE
↓
1
Data after CLK
↑
Data after LE
↓
0.7
1.4
t
h
Hold time
ns
CLK high or low
5