2 of 3
7628 Thorndike Road, Greensboro, NC 27409-9421 For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
Absolute Maximum Ratings
Parameter
Rating
Unit
Supply Voltage (VCC)
6.8
V
VTUNE
0 to 15
V
Storage Temperature
-65 to 150
°C
Operating Temperature
-55 to 100
°C
ESD JESD22 - A114 Human Body
Model (HBM)
V
Parameter
Specification
Unit
Condition
Min.
Typ.
Max.
Frequency
Frequency Range
5700
6700
MHz
100% Production Tested
Tuning Voltage
5700MHz
0
1.2
VDC
100% Production Tested
6700MHz
10.5
12
VDC
100% Production Tested
Tuning Sensitivity
70
210
MHz/V
100% Production Tested
Output Power
-4
-1
2
dBm
100% Production Tested
Output Phase Noise
10kHz
-74
-68
dBc/Hz
100% Production Tested
100kHz
-99
-93
dBc/Hz
100% Production Tested
1000kHz
-119
-113
dBc/Hz
100% Production Tested
Power Supply
4.85
5
5.15
V
100% Production Tested
Supply Current
19
23
mA
100% Production Tested
Harmonic Suppression
2nd Harmonic
-25
-10
dBc
100% Production Tested
3rd Harmonic
-30
-10
dBc
100% Production Tested
Spurious (Non-Harmonic)
-80
dBc
Frequency Pushing
2.5
5
MHz p-p
4.85V to 5.15V
Frequency Pulling
23
30
MHz p-p
12dB RL
Output Impedance
50
Tune Port Capacitance
22
pF
Caution! ESD sensitive device.
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
cause permanent damage to the device. Extended application of Absolute Maximum
Rating conditions to the device may reduce device reliability. Specified typical perfor-
mance or functional operation of the device under Absolute Maximum Rating condi-
tions is not implied.
RoHS status based on EUDirective2002/95/EC (at time of this document revision).
The information in this publication is believed to be accurate and reliable. However, no
responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any
infringement of patents, or other rights of third parties, resulting from its use. No
license is granted by implication or otherwise under any patent or patent rights of
RFMD. RFMD reserves the right to change component circuitry, recommended appli-
cation circuitry and specifications at any time without prior notice.