TPS5120EP
DUAL OUTPUT, TWOPHASE SYNCHRONOUS BUCK DC/DC CONTROLLER
SGLS224A JANUARY 2004 REVISED APRIL 2006
6
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
detailed description (continued)
overvoltage protection
For overvoltage protection (OVP), the TPS5120 monitors INV pin voltage. When the INV voltage is higher than
0.95 V (+12%), the OVP comparator output goes high and the FLT timer starts to charge an external capacitor
connected to FLT. After a set time, the FLT circuit latches the MOSFET drivers off.
undervoltage protection
For undervoltage protection (UVP), the TPS5120 monitors INV pin voltage. When the INV voltage is lower than
0.68 V (19.4%), the OVP comparator output goes high, and the FLT timer starts to charge an external capacitor
connected to FLT. Also, when the current comparator triggers the OCP, the UVP comparator detects the under
voltage output and starts the FLT capacitor charge. After a set time, the FLT circuit latches off all of the MOSFET
drivers.
FLT
When an OVP or UVP comparator output goes high, the FLT circuit starts to charge the FLT capacitor. If the
FLT pin voltage goes beyond a constant level, the TPS5120 latches the MOSFET drivers. At this time, the state
of MOSFET is different depending on the OVP alert and the UVP alert. Also, the enable time used to latch the
MOSFET driver is decided by the capacity of the FLT capacitor. The charging constant current value is also
different depending on whether it is an OVP alert or a UVP alert. The difference is shown in the following
equation:
FLT source current (OVP) = FLT source current (UVP)
× 5
shutdown
The TPS5120 can be shut down by grounding STBY1, STBY2, and 5V_STBY. The shutdown current is as low
as 1
A.
UVLO
When the input voltage goes up to about 4 V, the TPS5120 is operational. When the input voltage is lower than
the turnon value, the device is turned off. The typical hysteresis voltage is 40 mV.
phase Inverter
Phase inverter controls the phase of SMPS1 and SMPS 2. SMPS1 operates in phase with the OSC. SMPS2
operates 180
° out of phase from SMPS1. This allows smaller input capacitors to be used.
oscillator
TPS5120 has a triangle oscillator generator internal to the IC. The oscillation frequency is set by the size of the
capacitor connected to the CT pin. The voltage amplitude is 0.43 V ~ 1.17 V.