Fiber Optics
V23818-K305-V17 SFF MM 850nm 1.0625 GBd, 1.3 GBE 2x5 Trx (VF-45), w. collar
4
LASER SAFETY
This multimode Gigabit Ethernet transceiver is a Class 1 laser
product. It complies with IEC 825-1 and FDA 21 CFR 1040.10
and 1040.11. The transceiver must be operated under recom-
mended operating conditions. Because the transceiver design
is designed to be inherently eye safe, it does not require open
fiber control thus eliminating complex electronics or mechanics.
Caution
The use of optical instruments with this product will increase
eye hazard!
General Restrictions
Classification is valid only if the module is operated within the
specified temperature and voltage limits. The system using the
module must provide power supply protection that guarantees
that the system power source will cease to provide power if the
maximum recommended operation limit or more is detected on
the +3.3 V at the power source. The case temperature of the
module must be in the temperature range given in the recom-
mended operating limits. These limits guarantee the laser
safety.
Usage Restrictions
The optical ports of the modules shall be terminated with an
optical connector or with a dust plug.
Note
Failure to adhere to the above restrictions could result in a modifica-
tion that is considered an act of “manufacturing,” and will require,
under law, recertification of the modified product with the U.S. Food
and Drug Administration (ref. 21 CFR 1040.10 (i)).
Laser Data
Wavelength
Required Labels
Laser Emission
Pin Description
850 nm
Total output power (as defined by IEC: 50 mm
aperture at 10 cm distance)
<400 μW
Total output power (as defined by FDA: 7 mm
aperture at 20 cm distance)
<70 μW
Beam divergence
12
°
Class 1 Laser Product
IEC
Complies with 21 CFR
1040.10 and 1040.11
FDA
10 9 8 7 6
1 2 3 4 5
Tx
Rx
Indication of
laser aperture
and beam
Pin Name
Level/Logic Pin# Description
V
EEr
V
CCr
Receiver Power Supply
SD
Signal Detect
Receiver Signal Ground N/A
1
N/A
2
PECL
3
Normal Operation: Logic “1” Output, represents that light is present at receiver input
Fault Condition: Logic “0” Output
RD-
Received Data Out Not
PECL
4
RD+
Received Data Out
PECL
5
V
CCt
V
EEt
TDis
N/A
6
Transmitter Power Supply
N/A
7
Transmitter Signal Ground
TTL
8
Optional use for Laser based products only.
TD+
Transmit Data
PECL
9
Transmitter Data In
TD-
Transmit Data Not
PECL
10
Transmitter Data In
MS
MS
N/A
MS
Mounting Studs
The mounting studs are provided for transceiver mechanical attachment to the cir-
cuit board. They also provide an optional connection of the transceiver to the equip-
ment chassis ground.
The holes in the circuit board must be tied to chassis ground.