CHAPTER 6 TIMER ARRAY UNIT TAUS
User’s Manual U19678EJ1V1UD
293
(e) Start timing in capture & one-count mode
<1> Operation is enabled (TEn = 1) by writing 1 to the TSn.
<2> Enters the start trigger input wait status, and TCRn holds the initial value.
<3> On start trigger detection, 0000H is loaded to TCRn and count starts.
Figure 6-15. Start Timing (In Capture & One-count Mode)
TEn
fCLK
TCRn
0000H
TSn (write)
Count clockNote
Start trigger detection signal
TSn (write) hold signal
TIn edge detection signal
Start trigger input wait status
Initial value
<2>
<3>
<1>
Note
When the capture & one-count mode is set, the operation clock (fMCK) is selected as count clock
(CCS1n, CCS0n = 0).
Caution An input signal sampling error is generated since operation starts upon start trigger
detection (If the TIn pin input signal is used as a start trigger, an error of one count clock
occurs).