μ
PD784907, 784908
38
Data Sheet U11680EJ2V0DS00
8.3 Real-Time Output Port
The real-time output port outputs data stored in the buffer, synchronized with a timer/counter 1 match interrupt or
external interrupt. Thus, pulse output that is free of jitter can be obtained.
Therefore, the real-time output port is best suited to applications (such as open-loop control over stepping motors)
where an arbitrary pattern is output at arbitrary intervals.
As shown in Figure 8-5, the real-time output port is built around port 0 and the port 0 buffer register (P0H, P0L).
Figure 8-5. Block Diagram of Real-Time Output Port
4
4
4
P0L
P0H
Port 0 buffer register
8
4
8
P00
P07
Output latch (P0)
Real-time output port
control register
(RTPC)
Output trigger
control circuit
INTP0 (externally)
INTC10 (from timer/counter 1)
INTC11 (from timer/counter 1)
Internal bus