TQ5M34
Data Sheet
For additional information and latest specifications, see our website:
www.triquint.com
3
Cellular Band Typical Electrical Characteristics:
Parameter
Conditions
Mn.
Typ/Nom
Max.
Units
RF Frequency
869
881
894
MHz
LO Frequency
734
966
1029
MHz
IF Frequency
75
85
135
MHz
Conversion Gain
8.5
dB
Noise Figure
8.5
dB
Input 3
rd
Order Intercept
+10.0
dBm
Supply Current
10.0
mA
Note 1: Test Conditions: Vdd=+2.8V, RF=881MHz, LO=966MHz, IF=85MHz, LO input=-4dBm T
C
= 25
°
C, unless otherwise specified.
Korean PCS Band Typical Electrical Characteristics:
Parameter
Conditions
Mn.
Typ/Nom
Max.
Units
RF Frequency
1840
1855
1870
MHz
LO Frequency
1600
1635
2110
MHz
IF Frequency
180
220
240
MHz
Conversion Gain
8.5
dB
Noise Figure
8.5
dB
Input 3
rd
Order Intercept
+10.0
dBm
Supply Current
10.0
mA
Note 1: Test Conditions: Vdd=+2.8V, RF=1855MHz, LO=1635MHz, IF=220MHz, LO input=-4dBm T
C
= 25
°
C, unless otherwise specified.
US PCS Band Typical Electrical Characteristics:
Parameter
Conditions
Mn.
Typ/Nom
Max.
Units
RF Frequency
1930
1960
1990
MHz
LO Frequency
1690
1750
2230
MHz
IF Frequency
180
210
240
MHz
Conversion Gain
8.5
dB
Noise Figure
8.5
dB
Input 3
rd
Order Intercept
+10.0
dBm
Supply Current
10.0
mA
Note 1: Test Conditions: Vdd=+2.8V, RF=1960MHz, LO=1750MHz, IF=210MHz, LO input=-4dBm T
C
= 25
°
C, unless otherwise specified.