![](http://datasheet.mmic.net.cn/370000/TPS9103PW_datasheet_16743142/TPS9103PW_6.png)
TPS9103
POWER SUPPLY FOR GaAs POWER AMPLIFIERS
SLVS131A – OCTOBER 1995 – REVISED JULY 1996
6
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
6.5 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
PW
645 mW
353 mW
255 mW
Maximum values are calculated using a derating factor based on R
θ
JA = 154
°
C/W for the package. These devices are
mounted on an FR4 board with no special thermal considerations.
400
300
100
0
25
35
45
55
–
PD
500
600
700
65
75
85
200
PW Package
R
θ
JA = 154
°
C/W
TA – Free-Air Temperature –
°
C
Figure 1. Dissipation vs Free-Air Temperature
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
High-side switch input voltage range, BATT_IN (see Note 1)
Supply voltage range, V
CC
, V
DD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential voltage, |BATT_IN|–|GATE_BIAS|
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, SW_EN, EN, CLK, OSC_EN, PG
GATE_BIAS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, PG
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, BCLK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, GATE_BIAS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, BATT_OUT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Peak output current, BATT_OUT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum external clock frequency, CLK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Junction temperature range, T
J
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltages are with respect to device GND.
2. Differential voltage calculated: |VImax| + |GATE_BIAS|
–0.3 V to 15 V
–0.3 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 V
–0.3 V to V
CC
+ 0.3 V
. . . . . . . . . . . . . . . . . . . . . . . . . .
–5.5 V
5 mA
50 mA
10 mA
2 A
4 A
100 kHz
See Dissipation Rating Table
–25
°
C to 150
°
C
–65
°
C to 150
°
C