TPS75201Q, TPS75215Q, TPS75218Q, TPS75225Q, TPS75233Q WITH RESET
TPS75401Q, TPS75415Q, TPS75418Q, TPS75425Q, TPS75433Q WITH POWER GOOD
FAST-TRANSIENT-RESPONSE 2-A LOW-DROPOUT VOLTAGE REGULATORS
SLVS242B – MARCH 2000 – REVISED JUNE 2003
7
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating junction temperature range (unless otherwise noted)
Input voltage range
, V
I
Voltage range at EN
Maximum RESET voltage (TPS752xxQ)
Maximum PG voltage (TPS754xxQ)
Peak output current
Output voltage, V
O
(OUTPUT, FB)
Continuous total power dissipation
Operating virtual junction temperature range, T
J
Storage temperature range, T
stg
ESD rating, HBM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–0.3 V to 6.0 V
–0.3 V to 16.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16.5 V
16.5 V
Internally limited
5.5 V
See dissipation rating tables
–40
°
C to 125
°
C
–65
°
C to 150
°
C
2 kV
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltage values are with respect to network terminal ground.
DISSIPATION RATING TABLE 1 – FREE-AIR TEMPERATURES
TA < 25
°
C
POWER RATING
ABOVE TA = 25
°
C
2.9 W
PACKAGE
AIR FLOW
(CFM)
DERATING FACTOR
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
PWP§
0
23.5 mW/
°
C
34.6 mW/
°
C
23.8 mW/
°
C
57.9 mW/
°
C
1.9 W
1.5 W
300
4.3 W
2.8 W
2.2 W
PWP
0
3 W
1.9 W
1.5 W
300
7.2 W
4.6 W
3.8 W
§This parameter is measured with the recommended copper heat sink pattern on a 1-layer PCB, 5-in
×
5-in PCB, 1 oz. copper, 2-in
×
2-in coverage
(4 in2).
This parameter is measured with the recommended copper heat sink pattern on a 8-layer PCB, 1.5-in
×
2-in PCB, 1 oz. copper with layers 1,
2, 4, 5, 7, and 8 at 5% coverage (0.9 in2) and layers 3 and 6 at 100% coverage (6 in2). For more information, refer to TI technical brief SLMA002.
recommended operating conditions
MIN
MAX
UNIT
Input voltage, VI
#
Output voltage range, VO
Output current, IO
Operating virtual junction temperature, TJ
# To calculate the minimum input voltage for your maximum output current, use the following equation: VI(min) = VO(max) + VDO(max load).
2.7
5.5
V
1.5
5
V
0
2.0
A
°
C
–40
125