SWCS037G
– MAY 2008 – REVISED APRIL 2011
15.4 ESD Specifications
The device has built-in ESD protection to the limits specified below. It is recommended that the leads are
shorted together, or the device placed in conductive foam, during storage or handling to prevent
electrostatic damage.
ESD Method
Standard Reference
Performance
Human Body Model (HBM)
EIA / JESD22-A114D
2000V(1)
Charge Device Model (CDM)
EIA / JESD22-C101C
500V
(1)
The pin CLK32KOUT is 1500V HBM compliant.