TPS3305-18, TPS3305-25, TPS3305-33
DUAL PROCESSOR SUPERVISORS
SLVS198 – DECEMBER 1998
6
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD
(see Note1)
All other pins (see Note 1)
Maximum low output current, I
OL
Maximum high output current, I
OH
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
DD
)
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
DD
)
Continuous total power dissipation
Operating free-air temperature range, T
A
Storage temperature range, T
stg
Soldering temperature
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– 0.3 V to 7 V
5 mA
– 5 mA
±
20 mA
±
20 mA
See Dissipation Rating Table
–40
°
C to 85
°
C
–65
°
C to 150
°
C
260 C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to GND. For reliable operation the device must not be operated at 7 V for more than t = 1000 h
continuously.
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
17.1 mW/
°
C
5.8 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
DGN
2.14 mW
1.37 mW
1.11 mW
D
725 mW
464 mW
377 mW
recommended operating conditions at specified temperature range
MIN
MAX
UNIT
Supply voltage, VDD
Input voltage at MR and WDI, VI
Input voltage at SENSE1 and SENSE2, VI
High-level input voltage at MR and WDI, VIH
Low-level input voltage at MR and WDI, VIL
Input transition rise and fall rate at MR,
t/
V
Operating free-air temperature range, TA
2.7
6
V
0
VDD+0.3
V
0
(VDD+0.3)VIT/1.25V
V
0.7xVDD
V
0.3
×
VDD
50
V
ns/V
°
C
–40
85