TPS2202, TPS2202Y
DUAL-SLOT PC CARD POWER-INTERFACE SWITCHES
FOR SERIAL PCMCIA CONTROLLERS
SLVS103A – DECEMBER 1994 – REVISED AUGUST 1995
6–4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage range, V
DD
Input voltage range for card power: V
I(5V)
–0.3 V to 7 V
–0.3 V to 7 V
–0.3 V to V
I(5V)
–0.3 V to 14 V
–0.3 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
I(3V)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
I(12V)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current (each card): I
O(xVCC)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I
O(xVPP)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature range, T
J
Operating free-air temperature range, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
Logic input voltage
See Dissipation Rating Table
internally limited
internally limited
–40
°
C to 150
°
C
–40
°
C to 85
°
C
–55
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
260
°
C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
DISSIPATION RATING TABLE
DERATING FACTOR
ABOVE TA = 25
°
C
8.2 mW/
°
C
PACKAGE
TA
≤
25
°
C
POWER RATING
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
DB
1024 mW
655 mW
532 mW
DF
1158 mW
9.26 mW/
°
C
741 mW
602 mW
Maximum values are calculated using a derating factor based on R
θ
JA = 108
°
C/W for the package.
These devices are mounted on an FR4 board with no special thermal considerations.
recommended operating conditions
MIN
MAX
UNIT
Supply voltage, VDD
4.75
5.25
V
VI(5V)
VI(3V)
VI(12V)
IO(xVCC) at 25
°
C
IO(xVPP) at 25
°
C
0
5.25
VI(5V)
13.5
V
Input voltage range, VI
0
V
0
V
Output current IO
Output current, IO
1
A
150
mA
Clock frequency, fclock
Operating virtual junction temperature, TJ
VI(3V) should not be taken above VI(5V).
0
2.5
MHz
°
C
–40
125