AC Electrical Characteristics
(Continued)
Unless otherwise specified, T
A
e
25
§
C. All parameters are specified for a signal level of 0 dBm0 at 1 kHz. The 0 dBm0 level is
assumed to be 1.54 Vrms measured at the output of the transmit or receive filter. Limits printed in
BOLD
characters are
guaranteed for V
CC
e a
5.0V
g
5%, V
BB
e b
5.0V
g
5%; T
A
e
0
§
C to 70
§
C by correlation with 100% electrical testing at T
A
e
25
§
C. All other limits are assured by correlation with other production tests and/or product design and characterization. Typicals
specified at V
CC
e a
5.0V, V
BB
e b
5.0V, T
A
e
25
§
C.
Symbol
Parameter
Conditions
Min
Typ
Max
Units
RECEIVE OUTPUT POWER AMPLIFIER
IBP
Input Leakage Current, PWRI
b
3.2V
s
V
IN
s
3.2V
0.1
3
m
A
RIP
Input Resistance, PWRI
10
M
X
ROP1
Output Resistance, PWRO
a
, PWRO
b
Amplifiers Active
1
X
CLP
Load Capacitance, PWRO
a
, PWRO
b
500
pF
GA
p
a
GA
p
b
Gain, PWRI to PWRO
a
Gain, PWRI to PWRO
b
R
L
e
600
X
Connected Between
PWRO
a
and PWRO
b
, Input
Level
e
0 dBm0 (Note 4)
1
V/V
V/V
b
1
GR
p
L
Gaintracking Relative to 0 dBm0
Output Level, Including Receive Filter
V
e
2.05 Vrms, R
L
e
600
X
(Notes 4, 5)
V
e
1.75 Vrms, R
L
e
300
X
b
0.1
b
0.1
0.1
0.1
dB
dB
S/D
p
Signal/Distortion
V
e
2.05 Vrms, R
L
e
600
X
(Notes 4, 5)
V
e
1.75 Vrms, R
L
e
300
X
b
45
b
45
dB
dB
VOSP
Output DC Offset, PWRO
a
, PWRO
b
PWRI Connected to GNDA
b
50
50
mV
PSRR5
Power Supply Rejection of V
CC
or V
BB
PWRI Connected to GNDA
45
dB
Note 1:
Maximum power consumption will depend on the load impedance connected to the power amplifier. This specification listed assumes 0 dBm is delivered to
600
X
connected from PWRO
a
to PWRO
b
.
Note 2:
Voltage input to receive filter at 0V, VF
R
O connected to PWRI, 600
X
from PWRO
a
to PWRO
b
. Output measured from PWRO
a
to PWRO
b
.
Note 3:
The 0 dBm0 level for the filter is assumed to be 1.54 Vrms measured at the output of the XMT or RCV filter.
Note 4:
The 0 dBm0 level for the power amplifiers is load dependent. For R
L
e
600
X
to GNDA, the 0 dBm0 level is 1.43 Vrms measured at the amplifier output. For
R
L
e
300
X
the 0 dBm0 level is 1.22 Vrms.
Note 5:
VF
R
O connected to PWRI, input signal applied to VF
R
I.
Note 6:
Previous revisions of the datasheet did not clearly indicate this specification requires power amps in powerdown (PWRI
e b
5.25V).
Typical Application
TL/H/6660–2
Note 1:
Transmit voltage gain
e
R1
a
R2
R2
c
0
2 (The filter itself introduces a 3 dB gain), (R1
a
R2
t
10k)
Note 2:
Receive gain
e
R4
R3
a
R4
(R3
a
R4
t
10k)
Note:
In the configuration shown, the receive filter power amplifiers will drive a 600
X
T to R termination to a maximum signal level of 8.5 dBm. An alternative
arrangement, using a transformer winding ratio equivalent to 1.414:1 and 300
X
resistor, R
S
, will provide a maximum signal level of 10.1 dBm across a 600
X
termination impedance.
FIGURE 2