R
XC1800 Series of In-System Programmable Configuration PROMs
12
September 17, 1999 (Version 1.3)
Absolute Maximum Ratings
Notes
1:
Maximum DC undershoot below GND must be limited to either 0.5V or 10mA, whichever is easier to achieve. During
transitions, the device pins may undershoot to -2.0V or overshoot to +7.0V, provided this over- or undershoot lasts less then
10 ns and with the forcing current being limited to 200mA.
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress
ratings only, and functional operation of the device at these or any other conditions beyond those listed under Operating
Conditions is not implied. Exposure to Absolute Maximum Ratings conditions for extended periods of time may affect device
reliability.
Recommended Operating Conditions
2:
Quality and Reliability Characteristics
Symbol
Description
Value
Units
V
CC
Supply voltage relative to GND
-0.5 to +4.0
V
V
IN
Input voltage with respect to GND
-0.5 to +5.5
V
V
TS
Voltage applied to 3-state output
-0.5 to +5.5
V
T
STG
Storage temperature (ambient)
-65 to +150
°
C
T
SOL
Maximum soldering temperature (10 s @ 1/16 in.)
+260
°
C
T
J
Junction Temperature
+150
°
C
Symbol
Parameter
Min
Max
Units
V
CCINT
Commercial
Internal Voltage supply (T
A
= 0
°
C to +70
°
C)
3.0
3.6
V
Industrial
Internal Voltage supply (T
A
= -40
°
C to +85
°
C)
3.0
3.6
V
V
CCO
Supply voltage for output drivers for 3.3V operation
3.0
3.6
V
Supply voltage for output drivers for 2.5V operation
2.3
2.7
V
V
IL
Low-level input voltage
0
0.8
V
V
IH
High-level input voltage
2.0
5.5
V
V
O
Output voltage
0
V
CCO
V
Symbol
Description
Min
Max
Units
t
DR
Data Retention
10
-
Years
N
PE
Program/Erase Cycles (Endurance)
10,000
-
Cycles
V
ESD
Electrostatic Discharge (ESD)
2,000
-
Volts