TLE2426, TLE2426Y
THE “RAIL SPLITTER”
PRECISION VIRTUAL GROUND
SLOS098D – AUGUST 1991 – REVISED MAY 1998
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Continuous input voltage, V
I
Continuous filter trap voltage
Output current, I
O
Duration of short-circuit current at (or below) 25
°
C (see Note 1)
Continuous total power dissipation
Operating free-air temperature range, T
A
: C suffix
40 V
40 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
80 mA
unlimited
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
See Dissipation Rating Table
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M suffix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D or P package
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG or LP package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0
°
C to 70
°
C
–40
°
C to 85
°
C
–55
°
C to 125
°
C
–65
°
C to 150
°
C
I suffix
Storage temperature range, T
stg
260
°
C
300
°
C
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum dissipation
rating is not exceeded.
DISSIPATION RATING TABLE
DERATING FACTOR
ABOVE TA = 25
°
C
5.8 mW/
°
C
8.4 mW/
°
C
6.2 mW/
°
C
8.0 mW/
°
C
PACKAGE
TA
≤
25
°
C
POWER RATING
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
TA = 125
°
C
POWER RATING
D
JG
LP
P
725 mV
1050 mV
775 mV
1000 mV
464 mW
672 mW
496 mW
640 mW
377 mW
546 mW
403 mW
520 mW
145 mW
210 mW
155 mW
200 mW
recommended operating conditions
C SUFFIX
MIN
I SUFFIX
MIN
M SUFFIX
MIN
UNIT
MAX
MAX
MAX
Input voltage, VI
Operating free-air temperature, TA
4
40
4
40
4
40
V
°
C
0
70
–40
85
–55
125