SGLS131A JULY 2002 REVISED NOVEMBER 2003
11
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
TLC2274-EP electrical characteristics at specified free-air temperature, V
DD
±
=
±
5 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TLC2274-EP
MIN
TLC2274A-EP
MIN
TYP
UNIT
TA
TYP
300
MAX
2500
MAX
950
VIO
Input offset voltage
25
°
C
Full range
300
3000
1500
μ
V
α
VIO
Temperature coefficient of
input offset voltage
25 C
to 125
°
C
2
2
μ
V/
°
C
Input offset voltage long-
term drift (see Note 5)
VIC = 0 V,
RS = 50
VO = 0 V,
25
°
C
0.002
0.002
μ
V/mo
IIO
Input offset current
25
°
C
Full range
25
°
C
Full range
0.5
60
0.5
60
pA
800
800
IIB
Input bias current
1
60
1
60
pA
800
800
5
to 4
5
to 3.5
5.3
to 4.2
5
to 4
5
to 3.5
5.3
to 4.2
Common-mode input
voltage
25
°
C
VICR
,
RS = 50
| ≤
|
VIO
V
5 mV
Full range
IO = 20
μ
A
25
°
C
25
°
C
Full range
25
°
C
Full range
25
°
C
25
°
C
Full range
25
°
C
Full range
25
°
C
Full range
25
°
C
25
°
C
4.99
4.99
Maximum positive peak
output voltage
IO = 200 A
4.85
4.93
4.85
4.93
VOM+
4.85
4.85
V
IO = 1 mA
4.25
4.65
4.25
4.65
4.25
4.25
VIC = 0 V,
IO = 50
μ
A
4.99
4.99
Maximum negative peak
output voltage
VIC = 0 V,
IO = 500 A
4.85
4.91
4.85
4.91
VOM
4.85
4.85
V
VIC = 0 V,
IO = 5 A
3.5
4.1
3.5
4.1
3.5
3.5
Large-signal differential
voltage amplification
RL = 10 k
20
50
20
50
AVD
VO =
±
4 V
20
20
V/mV
RL = 1 M
300
1012
300
1012
rid
Differential input resistance
ri
Common-mode input
resistance
25
°
C
1012
1012
ci
Common-mode input
capacitance
f = 10 kHz,
N package
25
°
C
8
8
pF
zo
Closed-loop output
impedance
f = 1 MHz,
AV = 10
25
°
C
130
130
CMRR
Common-mode rejection
ratio
VIC = 5 V to 2.7 V
VO = 0 V,
25
°
C
Full range
25
°
C
Full range
25
°
C
Full range
75
80
75
80
dB
RS = 50
75
75
kSVR
Supply-voltage rejection
ratio (
VDD
±
/
VIO)
VIC = 0 V,
80
95
80
95
dB
VDD
±
=
±
2.2 V to
±
8 V,
No load
80
80
IDD
Supply current
VO = 0 V,
No load
4.8
6
6
4.8
6
6
mA
Full range is 55
°
C to 125
°
C for M level part.
NOTE 5: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150
°
C extrapolated
to TA = 25
°