
TL712
DIFFERENTIAL COMPARATOR
SLCS002B – JUNE 1983 – REVISED DECEMBER 1992
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
(see Note 1)
Input voltage, V
I
, any differential input
Differential input voltage, V
ID
(see Note 2)
Enable input voltage
Low-level output current, I
OL
Operating free-air temperature range, T
A
Storage temperature range
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG package
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D, P, or PW package
7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
25 V
±
25 V
7 V
50 mA
0
°
C to 70
°
C
– 65
°
C to 150
°
C
300
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated in the “recommended operating conditions” section of
this specification is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, except differential voltages, are with respect to the network ground.
2. Differential voltage values are at IN+ with respect to IN–.
recommended operating conditions
MIN
NOM
MAX
UNIT
Supply voltage, VCC
Common-mode input voltage, VIC
High-level output current, IOH
Low-level output current, IOL
Operating free-air temperature, TA
4.75
5
5.25
V
0
5
V
–1
mA
16
mA
°
C
0
70
electrical characteristics at V
CC
= 5 V, T
A
= 25
°
C
PARAMETER
TEST CONDITIONS
MIN
–100
TYP
MAX
UNIT
VT
Vhys
VOH
VOL
IOZ
II
IIH
Threshold voltage (VT+ and VT–)
Hysteresis (VT+ – VT–)
High-level output voltage
VICR = 0 to 5 V
100
mV
5
mV
VID = 100 mV,
VID = – 100 mV,
VO = 2.4 V
VI = 5.5 V
VIH = 2.7 V
VIL = 0.4 V
IOH = –1 mA
IOL = 16 mA
2.7
3.5
V
Low-level output voltage
0.4
0.5
V
μ
A
μ
A
μ
A
μ
A
k
W
Off-state output current
–20
Enable current
100
High-level enable current
20
IIL
ri
ro
IOS
ICC
The algebraic convention, where the more negative limit is designated as minimum, is used in this data sheet for input threshold voltage levels
only.
Low-level enable current
–360
DIfferential input resistance
4
Output resistance
100
Short-circuit output current
–15
–85
mA
Supply current
VID = 0,No load
17
20
mA
switching characteristics, V
CC
= 5 V, T
A
= 25
°
C
PARAMETER
TEST CONDITIONS
MIN
TYP
25
25
MAX
UNIT
ns
ns
tPLH
tPHL
NOTE 3: The response time specified is for a 100-mV input step with 5-mV overdrive (105 mV total), and is the interval between the input step
function and the instant when the output crosses 2.5 V.
Propagation delay time, low-to-high-level output
Propagation delay time, high-to-low-level output
TTL load
See Figure 1
See Note 3