TC241
780-
×
488-PIXEL CCD IMAGE SENSOR
SOCS006C – AUGUST 1986 – REVISED DECEMBER 1991
10
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
: ADB, CDB, IDB, TDB (see Note 1)
Input voltage range, V
I
: ABG, IAG, SAG, SRG, TRG
Operating free-air temperature range, T
A
Storage temperature range, T
STG
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
0 V to 15 V
–15 V to 15 V
–10
°
C to 45
°
C
–30
°
C to 85
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
260
°
C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to the substrate terminal.
recommended operating conditions
MIN
NOM
MAX
UNIT
Supply voltage, VCC
Substrate bias voltage
ADB, CDB, IDB, TDB
11
12
13
V
0
V
High level
Intermediate level§
1.5
2
2.5
IAG
–5
Low level
–10
–9
–8
SRG1 SRG2 SRG3
SRG1, SRG2, SRG3
High level
1.5
2
2.5
Low level
–10
–9
–8
Input voltage V
Input voltage, VI
High level
Intermediate level§
2
4
6
V
ABG
–2.5
Low level
–7
SAG
High level
1.5
2
2.5
Low level
–10
–9
–8
TRG
High level
1.5
2
2.5
Low level
–10
–9
–8
IAG, SAG
2.05
Clock frequency, fclock
SRG1, SRG2, SRG3, TRG
4.77
MHz
ABG
2.05
Load capacitance
OUT1, OUT2, OUT3
8
pF
Operating free-air temperature, TA
The algebraic convention, in which the least-positive (most negative) value is designated minimum, is used in this data sheet for clock voltage
levels.
§Adjustment is required for optimal performance.
–10
45
°
C