TL05x, TL05xA, TL05xY
ENHANCED-JFET LOW-OFFSET
OPERATIONAL AMPLIFIERS
SLOS178 – FEBRUARY 1997
7
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC+
(see Note 1)
Supply voltage, V
CC–
(see Note 1)
Differential input voltage (see Note 2)
Input voltage range, V
I
(any input, see Notes 1 and 3)
Input current, I
I
(each input)
Output current, I
O
(each output)
Total current into V
CC+
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current out of V
CC–
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duration of short-circuit current at (or below) 25
°
C (see Note 4)
Continuous total power dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: C suffix
I suffix
M suffix
Storage temperature range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Case temperature for 60 seconds: FK package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16inch) from case for 10 seconds: D, N, or P package
Lead temperature 1,6 mm (1/16inch) from case for 60 seconds: J or JG package
18 V
–18 V
±
30 V
±
15 V
±
1 mA
±
80 mA
160 mA
160 mA
unlimited
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
See Dissipation Rating Table
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0
°
C to 70
°
C
–40
°
C to 85
°
C
–55
°
C to 125
°
C
–65
°
C to 150
°
C
260
°
C
260
°
C
300
°
C
. . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, except differential voltages, are with respect to the midpoint between VCC+ and VCC–.
2. Differential voltages are at IN+ with respect to IN–.
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum
dissipation rating is not exceeded.
DISSIPATION RATING TABLE
DERATING FACTOR
ABOVE TA = 25
°
C
5.8 mW/
°
C
7.6 mW/
°
C
11.0 mW/
°
C
11.0 mW/
°
C
8.4 mW/
°
C
12.6 mW/
°
C
8.0 mW/
°
C
PACKAGE
TA
≤
25
°
C
POWER RATING
725 mW
950 mW
1375 mW
1375 mW
1050 mW
1575 mW
1000 mW
TA = 70
°
C
POWER RATING
464 mW
608 mW
880 mW
880 mW
672 mW
1008 mW
640 mW
TA = 85
°
C
POWER RATING
377 mW
494 mW
715 mW
715 mW
546 mW
819 mW
520 mW
TA = 125
°
C
POWER RATING
145 mW
190 mW
275 mW
275 mW
210 mW
315 mW
200 mW
D–8
D–14
FK
J
JG
N
P
recommended operating conditions
C SUFFIX
MIN
±
5
–1
I SUFFIX
MIN
±
5
–1
M SUFFIX
MIN
±
5
–1
UNIT
MAX
±
15
MAX
±
15
MAX
±
15
Supply voltage, VCC
±
V
Common mode input voltage V
Common-mode input voltage, VIC
VCC
±
=
±
5 V
VCC
±
=
±
15 V
4
4
4
V
–11
11
–11
11
–11
11
Operating free-air temperature, TA
0
70
–40
85
–55
125
°
C