      參數(shù)資料
      型號: TK11338BMCB
      廠商: TOKO Inc.
      英文描述: VOLTAGE REGULATOR WITH ON/OFF SWITCH
      中文描述: 調(diào)壓器ON / OFF開關(guān)
      文件頁數(shù): 7/13頁
      文件大小: 152K
      代理商: TK11338BMCB
      May, 1997 TOKO, Inc.
      Page 7
      TK113xxB
      DEFINITION AND EXPLANATION OF TECHNICAL TERMS
      OUTPUT VOLTAGE (V
      O
      )
      The output voltage is specified with V
      IN
      = (V
      O(TYP)
      + 1 V)
      and I
      O
      = 30 mA.
      DROPOUT VOLTAGE (V
      DROP
      )
      The dropout voltage is the difference between the input
      voltage and the output voltage at which point the regulator
      starts to fall out of regulation. Below this value, the output
      voltage will fall as the input voltage is reduced. It is
      dependent upon the load current and the junction tempera-
      ture.
      OUTPUT CURRENT (I
      O
      MAX)
      The rated output current is specified under the condition
      where the output voltage drops 0.3 V below the value
      specified with I
      O
      = 30 mA. The input voltage is set to V
      O
      +1
      V, and the current is pulsed to minimize temperature effect.
      CONTINUOUS OUTPUT CURRENT (I
      O
      )
      Normal operated output current. This is limited by package
      power dissipation.
      PULSE OUTPUT CURRENT (I
      O (PULSE)
      )
      Max pulsewidth 5ms, Duty cycle 12.5%: pulse load only
      LINE REGULATION (LINE REG)
      Line Regulation is the ability of the regulator to maintain a
      constant output voltage as the input voltage changes. The
      line regulation is specified as the input voltage is changed
      from V
      IN
      = V
      O
      + 1V to V
      IN
      = V
      O
      + 6V.
      LOAD REGULATION (LOAD REG)
      Load regulation is the ability of the regulator to maintain a
      constant output voltage as the load current changes. It is
      a pulsed measurement to minimize temperature effects
      with the input voltage set to V
      IN
      = V
      O
      +1 V. The load
      regulation is specified under two output current step condi-
      tions of 1 mA to 60 mA and 1 mA to 100 mA.
      QUIESCENT CURRENT (IQ)
      The quiescent current is the current which flows through
      the ground terminal under no load conditions (I
      O
      = 0 mA)
      RIPPLE REJECTION RATIO
      Ripple rejection is the ability of the regulator to attenuate
      the ripple content of the input voltage at the output. It is
      specified with 100 mVrms, 400 Hz superimposed on the
      input voltage, where V
      IN
      = V
      O
      + 1.5 V. The output decoupling
      capacitor is set to 10
      μ
      F, the noise bypass capacitor is set
      to 0.1
      μ
      F, and the load current is set to 30 mA. Ripple
      rejection is the ratio of the ripple content of the output vs. the
      input and is expressed in dB.
      STANDBY CURRENT
      Standby current is the current which flows into the regulator
      when the output is turned off by the control function (V
      CONT
      = V
      IN
      .) It is measured with V
      IN
      = 8 V (9 V for the 8 V output
      device.)
      SENSOR CIRCUIT
      Over current sensor
      The overcurrent sensor protects the device in the event
      that the output is shorted to ground.
      Thermal sensor
      The thermal sensor protects the device in the event
      that the junction temperature exceeds the safe value
      (T
      J
      = 150
      °
      C). This temperature rise can be caused by
      external heat, excessive power dissipation caused by
      large input to output voltage drops, or excessive output
      current. The regulator will shut off when the tempera-
      ture exceeds the safe value. As the junction tempera-
      tures decrease, the regulator will begin to operate
      again. Under sustained fault conditions, the regulator
      output will oscillate as the device turns off then resets.
      Damage may occur to the device under extreme fault
      conditions.
      Reverse Voltage Protection
      Reverse voltage protection prevents damage due to
      the output voltage being higher than the input voltage.
      This fault condition can occur when the output capaci-
      tor remains charged and the input is reduced to zero,
      or when an external voltage higher than the input
      voltage is applied to the output side.
      相關(guān)PDF資料
      PDF描述
      TK11338BMCL VOLTAGE REGULATOR WITH ON/OFF SWITCH
      TK11338BMIB VOLTAGE REGULATOR WITH ON/OFF SWITCH
      TK11338BMIL VOLTAGE REGULATOR WITH ON/OFF SWITCH
      TK11338BUIB VOLTAGE REGULATOR WITH ON/OFF SWITCH
      TK11338BUIL VOLTAGE REGULATOR WITH ON/OFF SWITCH
      相關(guān)代理商/技術(shù)參數(shù)
      參數(shù)描述
      TK11338BMCL 制造商:TOKO 制造商全稱:TOKO, Inc 功能描述:VOLTAGE REGULATOR WITH ON/OFF SWITCH
      TK11338BMIB 制造商:TOKO 制造商全稱:TOKO, Inc 功能描述:VOLTAGE REGULATOR WITH ON/OFF SWITCH
      TK11338BMIL 制造商:TOKO 制造商全稱:TOKO, Inc 功能描述:VOLTAGE REGULATOR WITH ON/OFF SWITCH
      TK11338BUCB 制造商:TOKO 制造商全稱:TOKO, Inc 功能描述:VOLTAGE REGULATOR WITH ON/OFF SWITCH
      TK11338BUCL 制造商:TOKO 制造商全稱:TOKO, Inc 功能描述:VOLTAGE REGULATOR WITH ON/OFF SWITCH