Filename: tfs 92b.doc
Version 1.2
03.05.2006
VI TELEFILTER
Filter specification
TFS 92B
1/5
Tele Filter GmbH
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Measurement condition
Ambient temperature:
23
°C
Input power level:
0
dBm
Terminating impedance: *
Input:
2530 || -8,1 pF
Output:
2380 || -9,4 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 92B is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB
filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the
frequency response of the filter in the operating temperature range.
D a t a
typ. value
tolerance / limit
Insertion loss
ae
11,3
dB
max.
15
dB
(reference level)
Nominal frequency
fN
-
92,0
MHz
Centre frequency
fC
92,01
MHz
-
Passband
PB
fN
±
500
kHz
Pass band ripple
0,4
dB
max.
0,8
dB
Amplitude ripple in any 112,5 kHz segment within PB
p-p
0,2
dB
max.
0,5
dB
Relative attenuation
arel
fN
… fN ±
500
kHz
0,4
dB
max.
0,8
dB
fN
±
1,1
MHz … fN ±
1,5
MHz
47
dB
min.
39
dB
fN
±
1,5
MHz … fN ±
3
MHz
48
dB
min.
40
dB
0,3
MHz … fN -
3
MHz
60
dB
min.
50
dB
fN
+
3
MHz … fN +
1
GHz
65
dB
min.
50
dB
Group delay
at fN
2,3
s
max.
4
s
Group delay ripple in any 112,5 kHz segment within PB
60
ns
max.
120
ns
Phase linearity in any 112,5 kHz segment within PB
p-p
1,4
deg
max.
5
deg
Triple transit response suppression
38
dB
min.
35
dB
Input power level
-
max.
23
dBm**)
Operating temperature range
OTR
-
- 40 °C ... + 70°C
Storage temperature range
-
- 40 °C ... + 100°C
Frequency inversion temperature
15
°C
-
Temperature coefficient of frequency
TCf **
-0,036
ppm/K
2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) This power level is only allowed for short term operation (10% of the life time), the max. input power for continuous operation is max.15dBm only
***) f(Hz) = TCf(ppm/K
2) x (T-T0)2 x fTo(MHz)
Generated:
Checked / Approved: