Tfs600.doc
VI
TELEFILTER
version 1.1
01.03.2001
Filter Specification
TFS 600
1/5
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail:
vti@vtinh.com
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances
23
°
C
0 dBm
for input: 270
// -0,8pF
for output: 285
// -0,8pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 600 is the insertion loss. The insertion loss ae is defined as the insertion loss at the
nominal frequency f
. The centre frequency f
is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss ae. The nominal frequency f
N
is fixed on 600 MHz without tolerance. The specified values have to be reached in
operating temperature range.
D a t a
typ. value
tolerance/limit
Insertion loss
(Reference level)
ae
-
max.
6,5
dB
Nominal frequency
f
N
-
600,000 MHz
Centre frequency
f
C
600,02
MHz
-
1 dB bandwidth
bw
-
min.
32
kHz
Relative attenuation
fN
fN ±800 kHz
fN ±
5 MHz ... fN ± 20 MHz
arel
... fN ± 16 kHz
... fN ± 5 MHz
-
max.
1
dB
min.
20
dB
-
min.
30
dB
VSWR
In 1 dB bandwidth
-
min.
2 : 1
Input power
-
max.
3
dBm
Operating temperature range
- 5
°
C ... + 70
°
C
Storage temperature range
- 30
°
C ... + 80
°
C
Temperature coefficient of frequency
TC
- 0.036
ppm/K2
Frequency inversion temperature
40
°C
Generated:
Checked / approved: