Filename: tfs 35d.doc
Version 1.3
19.08.2005
VI TELEFILTER
Filter specification
TFS 35D
1/5
Tele Filter GmbH
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Description
IF filter for digital cable TV
Measurement condition
Ambient temperature TA:
25
°C
Input power level:
0
dBm
Terminating impedance:
source:
50
load:
2 k
II 3 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 35D is the insertion loss. The insertion loss ae is defined as the insertion loss at the nominal
frequency fN. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the
insertion loss ae.
D a t a
typ. Value
Limit
Insertion loss
19,6
MHz
20,3
±
1,5
dB
(reference level)
Nominal frequency
fN
-
35,875 MHz
Centre frequency
fc at ambient temperature TA
-
35,875 MHz ± 0,055 MHz
Bandwidth
1 dB
7,45
MHz
-
3 dB
7,85
MHz
-
30 dB
9,24
MHz
-
Group delay ripple
p-p in fc ± 3,75 MHz
40
ns
-
Relative attenuation
arel
32,07
MHz
1,6
dB
-
39,68
MHz
1,2
dB
1,1
±
1
dB
31,90
MHz
3,8
dB
3,1
±
1,2
dB
39,86
MHz
3,4
dB
3,2
±
1,2
dB
31,00
MHz
41
dB
min.
35
dB
47,00
MHz
47
dB
min.
42
dB
lower side lobe
24,75 ... 29,25
MHz
42
dB
min.
36
dB
29,25 ... 31,00
MHz
39
dB
min.
32
dB
upper side lobe
40,65 ... 43,25
MHz
35
dB
min.
32
dB
43,25 ... 49,75
MHz
41
dB
min.
36
dB
Reflected wave signal suppression
55
dB
min.
42
dB
1,2 s...6,0 s after main pulse
Feedthrough signal suppression
53
dB
min.
50
dB
Operable temperature range
-
-25 ...
65
° C
Storage temperature range
-
-40 ...
85
° C
Temperature coefficient of frequency TCf*
- 72
ppm / K
-
*)
fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
generated:
checked / approved: