Filename: tfs 1552.doc
Version 1.3
16.05.2006
VI TELEFILTER
Filter specification
TFS 1552
1/5
Tele Filter GmbH
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Measurement condition
Ambient temperature:
23
°C
Input power level:
0
dBm
Terminating impedance: *
Input:
138 || -1,42 pF
Output:
138 || -1,42 pF
Characteristics
Remark:
The minimum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1552,0 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
D a t a
typ. value
tolerance / limit
Insertion loss
ae
4,3
dB
max.
6,0
dB
Nominal frequency
fN
-
1552,0
MHz
Passband
PB
-
fN
±
2,2
MHz
Pass band ripple
1,2
dB
max.
2,0
dB
Absolute attenuation
aabs
1440
MHz
… 1547
MHz
20
dB
min.
9
dB
1559
MHz
… 1600
MHz
31
dB
min.
23
dB
Group delay ripple
28
ns
max.
100
ns
Input power level
-
max.
20
dBm
Operating temperature range
OTR
-
- 10 °C ... + 60 °C
Storage temperature range
-
- 45 °C ... + 85 °C
Frequency inversion temperature
40
°C
-
Temperature coefficient of frequency
TCf **
-0,051
ppm/K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**)
f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
Generated: