electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54LVTH241
SN74LVTH241
UNIT
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
UNIT
VIK
VCC = 2.7 V,
II = 18 mA
1.2
V
VCC = 2.7 V to 3.6 V,
IOH = 100 A
VCC0.2
VOH
VCC = 2.7 V,
IOH = 8 mA
2.4
V
VOH
VCC = 3 V
IOH = 24 mA
2
V
VCC = 3 V
IOH = 32 mA
2
VCC = 2.7 V
IOL = 100 A
0.2
VCC = 2.7 V
IOL = 24 mA
0.5
VOL
IOL = 16 mA
0.4
V
VOL
VCC = 3 V
IOL = 32 mA
0.5
V
VCC = 3 V
IOL = 48 mA
0.55
IOL = 64 mA
0.55
VCC = 0 or 3.6 V,
VI = 5.5 V
10
II
Control inputs
VCC = 3.6 V,
VI = VCC or GND
±1
A
II
Data inputs
VCC = 3.6 V
VI = VCC
1
A
Data inputs
VCC = 3.6 V
VI = 0
5
Ioff
VCC = 0,
VI or VO = 0 to 4.5 V
±100
A
VCC = 3 V
VI = 0.8 V
75
II(hold)
Data inputs
VCC = 3 V
VI = 2 V
75
A
II(hold)
Data inputs
VCC = 3.6 V,
VI = 0 to 3.6 V
500
750
A
IOZH
VCC = 3.6 V,
VO = 3 V
5
A
IOZL
VCC = 3.6 V,
VO = 0.5 V
5
A
IOZPU
VCC = 0 to 1.5 V, VO = 0.5 V to 3 V,
OE/OE = don’t care
±100
A
IOZPD
VCC = 1.5 V to 0, VO = 0.5 V to 3 V,
OE/OE = don’t care
±100
A
VCC = 3.6 V,
Outputs high
0.19
ICC
VCC = 3.6 V,
IO = 0,
V = V
or GND
Outputs low
5
mA
ICC
IO = 0,
VI = VCC or GND
Outputs disabled
0.19
mA
ICC§
VCC = 3 V to 3.6 V, One input at VCC 0.6 V,
Other inputs at VCC or GND
0.2
mA
Ci
VI = 3 V or 0
3
pF
Co
VO = 3 V or 0
7
pF
On products compliant to MIL-PRF-38535, this parameter is not production tested.
All typical values are at VCC = 3.3 V, TA = 25°C.
This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to another.
§ This is the increase in supply current for each input that is at the specified TTL voltage level, rather than VCC or GND.
PRODUCT PREVIEW information concerns products in the formative or
design phase of development. Characteristic data and other
specifications are design goals. Texas Instruments reserves the right to