SMQ320C32
DIGITAL SIGNAL PROCESSOR
SGUS027C – APRIL 1998 – REVISED OCTOBER 2001
17
POST OFFICE BOX 1443
HOUSTON, TEXAS 77251–1443
absolute maximum ratings over specified temperature ranges (unless otherwise noted)
Supply voltage range, VCC (see Note 1)
–0.3 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range
– 0.3 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, VO
– 0.3 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous power dissipation (see Note 2)
1.95 W
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating case temperature, TC
– 55
°C to 125°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature, Tstg
– 55
°C to 150°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values are with respect to VSS.
2. This value calculated for the ’C32-40. Actual operating power is less. This value was obtained under specially produced worst-case
test conditions which are not sustained during normal device operation. These conditions consist of continuous parallel writes of
a checkerboard pattern to the external bus at the maximum rate possible. See normal (IDD) current specification in the electrical
characteristics table and see the Calculation of TMS320C30 Power Dissipation Application Report (literature number SPRA020).
recommended operating conditions (see Note 3)
MIN
NOM
MAX
UNIT
VDD
Supply voltage (DVDD, VDDL)
4.75
5
5.25
V
VSS
Supply voltage (CVSS, VSSL, IVSS, DVSS, VSUBS)
0
V
High le el inp t oltage
CLKIN
2.6
VDD + 0.3*
V
VIH
High-level input voltage
All other inputs
2
VDD + 0.3*
V
VIL
Low-level input voltage
– 0.3*
0.8
V
IOH
High-level output current
– 300
A
IOL
Low-level output current
2
mA
TC
Operating case temperature (see Note 4)
– 55
125
°C
All nominal values are at VDD = 5 V, TA (ambient-air temperature)= 25°C.
* This parameter is not production tested.
NOTE 3: All input and output voltage levels are TTL compatible.
NOTE 4: TC MAX at maximum rated operating conditions at any point on case. TC MIN at initial (time zero) power-up.