SMH4814
Preliminary Information
Summit Microelectronics, Inc
2080 2.0 07/21/05
33
Register R05 – Pull-downs, Pull-ups, current regulation and fault latch.
Bits D[7:6] control the fast pull down level by the number of diodes connected in series with the gate pull-down
transistor of the Quick Trip sensor. Bits D[5:4] control the GATEA/GATEB Pull-up Current. Bit D[3] controls the
Current Regulation. Bit D[2] controls the Fault Latches Off versus Duty Cycle. Bits D[1:0] control the Drain Sense
Glitch Filter.
Register R05
D7
D6
D5
D4
D3
D2
D1
D0
Action
0
0
-
-
-
-
-
-
Fast pull down level - no diodes connected in series
with the gate pull-down transistor of the Quick Trip
sensor.
Fast pull down level –1 diode connected in series
with the gate pull-down transistor of the Quick Trip
sensor.
Fast pull down level - 2 diodes connected in series
with the gate pull-down transistor of the Quick Trip
sensor.
Fast pull down level – 3 diodes connected in series
with the gate pull-down transistor of the Quick Trip
sensor.
VGATEA/VGATEB Pull-up Current 10
μ
a
VGATEA/VGATEB Pull-up Current 50
μ
a
VGATEA/VGATEB Pull-up Current 100
μ
a
VGATEA/VGATEB Pull-up Current 200
μ
a)
Enable Current regulation.
Disable Current regulation.
Fault condition must be manually cleared
Fault cleared after Duty cycle timeout
Drain Sense Glitch Filter is 1
μ
s.
Drain Sense Glitch Filter is 14
μ
s.
Drain Sense Glitch Filter is 40
μ
s.
Drain Sense Glitch Filter is 119
μ
s.
0
1
-
-
-
-
-
-
1
0
-
-
-
-
-
-
1
1
-
-
-
-
-
-
-
-
0
0
-
-
-
-
-
-
0
1
-
-
-
-
-
-
1
0
-
-
-
-
-
-
1
-
-
-
-
-
1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0
1
-
-
-
-
-
0
1
-
-
-
-
-
-
-
-
-
0
0
0
1
1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
0
1
CONFIGURATION REGISTERS (CONTINUED)