3
SMFLSERIES
65 WATT
DC/DC C
ONVERTERS
DUAL OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
SMFL2805D
MIN
TYP
4.95
5.00
4.92
5.00
SMFL2812D
MIN
TYP
11.88 12.00
11.82 12.00
SMFL2815D
MIN
TYP
CONDITIONS
Tc = 25°C–V
OUT
MAX
5.05
5.08
MAX
12.12 14.85 15.00
12.18
14.77 15.00
MAX
15.15
15.23
UNITS
VDC
OUT
OUTPUT CURRENT
1
V
IN
= 16 TO 40 VDC
EACH OUTPUT
0
—
7
0
—
3.5
0
—
3.03
A
TOTAL OUTPUT
0
—
10
0
—
5
0
—
4.33
OUTPUT POWER
V
IN
= 16 TO 40 VDC
0
—
50
0
—
60
0
—
65
W
OUTPUT RIPPLE
VOLTAGE ± V
OUT
LINE REGULATION
10 kHz - 2 MHz
—
50
100
—
50
120
—
50
150
mV p-p
V
IN
= 16 TO 40 VDC
+V
OUT
–V
OUT
—
0
50
—
0
50
—
0
50
mV
—
25
100
—
25
100
—
25
100
LOAD REGULATION
NO LOAD TO FULL
+V
OUT
—
—
25
0
50
—
—
50
10
120
100
—
—
50
10
150
100
mV
–V
OUT
SEE NOTE 2
SEE NOTE 3
100
CROSS REGULATION
—
—
5
3
8
6
—
—
2
2
4
4
—
—
2
2
4
4
%
INPUT VOLTAGE
CONTINUOUS
TRANSIENT
4, 7
50 ms.
NO LOAD
FULL LOAD
INHIBITED - INH1
INHIBITED - INH2
16
—
—
—
—
—
28
—
50
—
9
35
40
50
120
2.40
14
70
16
—
—
—
—
—
28
—
50
—
9
35
40
50
100
2.80
14
70
16
—
—
—
—
—
28
—
50
—
9
35
40
50
100
3.00
14
70
VDC
V
mA
A
INPUT CURRENT
mA
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT
5
10 kHz - 10 MHz
BALANCED LOAD
POWER DISSIPATION
SHORT CIRCUIT
RECOVERY
50 %–100%– 50% LOAD
TRANSIENT
RECOVERY
6, 7
16 – 40 – 16 V
IN
TRANSIENT
7
—
75
15
80
50
—
—
81
15
86
50
—
—
82
15
87
50
—
mA p-p
%
—
—
12.5
1.5
16
4.0
—
—
10
1.5
14
4.0
—
—
10
1.5
14
4.0
W
ms
STEP LOAD
RESPONSE ± V
OUT
—
250
350
—
450
600
—
500
600
mV pk
—
1.5
3.0
—
1.5
3.0
—
1.5
3.0
ms
STEP LINE
6, 7
RESPONSE ± V
OUT
—
250
300
—
250
400
—
250
400
mV pk
RECOVERY
DELAY
OVERSHOOT
7
—
—
200
3.5
300
6
—
—
200
3.5
300
6
—
—
200
3.5
300
6
μs
ms
START–UP
—
0
25
—
0
50
—
0
50
mV pk
Notes
1. Up to 70% of the total output power is available from either output providing
the opposite output is simultaneously carrying 30% of the total power.
2. Effect on the negative output under the following conditions:
+P
30% to 70%; –P
70% to 30%
3. Effect on the negative output under the following conditions:
+P
out
50%; –P
out
10% to 50%
4. Unit will shut down above approximately 45V but will be undamaged and will
restart when voltage drops into normal range.
5. Indefinite short circuit protection not guaranteed above 125°C case.
6. Recovery time is measured from application of the transient to point at which
Vout is within 1% of final value.
7. Guaranteed but not tested.
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, radiation level O, unless otherwise specified.