SLE 4432
SLE 4442
SLE 4440
SLE 4441
Semiconductor Group
8
Data Sheet Extension 09.98
2.
Coding
SLE 4432, SLE 4442, SLE 4440 and SLE 4441 are delivered with a customer related unique
code in order to allow an unambiguous identification of the application. Thus a terminal can
clearly accept or reject a card after reading the Answer-to-Reset and the identification data. The
Answer-to-Reset (ATR) for synchronous IC cards according to ISO/IEC 7816 is a standardized
procedure allowing to identify an IC card (ICC) supporting the synchronous Answer-to-Reset. The
Answer-to-Reset data allow an interface device to select the appropriate chip type and operate
the ICC according to the data sheet of the chip.
Two different coding schemes apply
Extended coding using encoded BER-TLV data objects according to ISO/IEC 7816-4
16-bit manufacturer code registered at Pro Electron
Both schemes identify the application by the registered application provider identifier RID
according to ISO/IEC 7816-5
2.1.
Registered Application Provider Identifier RID
The application is generally identified by the customer specific 5-byte registered application
provider identifier
RID
according to ISO/IEC 7816
-5 using the registration category values ‘A’ and
‘D’. The RID is a part of the
AID
. Thus the AID is constructed as following:
Application identifier
AID
Registered application provider identifier
RID (5 byte)
Proprietary application provider identifier
extension
PIX (
≤
11 byte)
Registered application provider identifier RID
Customer specific RID provided by the registration authority to the applicant
RID
‘
A
x xx xx xx xx’
International registration
‘
D
c cc xx xx xx’
National registration
‘c cc’
Country indicator
‘xx xx xx’
Application provider sequence no.
Meaning
Comment
RID is registered by Tele Denmark
RID is registered by a national authority
Country code according to ISO 3166
Provided by national registration authority
Proprietary application provider identifier extension PIX
Extension for the RID holder in order to diversify own applications
Application forms for a RID are printed in the Annex A of ISO/IEC 7816-5.
For international registration one has to apply at the acting registration authority Tele Denmark
for a RID indicated by ‘A’. The contact address is printed in ISO/IEC 7816-5
For national registration one has to apply at the relevant national standardization body or its
acting registration authority for a RID indicated by ‘D’ followed by the country code
The RID is provided by the customer to Siemens.