5/10
sames
SA2007M
INPUT SIGNALSVREF
A bias resistor of 24k
W
sets optimum bias and reference
conditions on chip. Calibration of the SA2007M should be
done on the voltage input as described in Typical Application.
Motor pulse rate select (MP1 and MP0)
The pulse rate of the motor driver output of the SA2007M is
selected by the inputs MP1 and MP0. Three pulses rate
options are available as shown in the following table:
Pulse rate selection
Figure 4: Motor drive on MON and MOP pins
Please note that the device will not perform metering functions
as described in this document while in test mode.
Rated condition select (RATED)
The rated condition select pin gives the option of having a 3:2:1
scaling ratio for the rated meter current. This feature is
particularly useful in circumstances where a manufacturer
requires a meter for use in a system rated for two different
conditions, for example 230V/60A and 230V40A. With the
rated condition select the SA2007M allow for the development
of different rated meters requiring minimal changes. The
following table below lists the option available (assuming the
rated condition to be 230V/60A).
Rated condition select (RATED)
Figure 5: LED pulse output
OUTPUT SIGNALS
Motor output (MOP, MON)
The MON pulse will follow the MOP pulse within 142ms. This
prevents that the motor armature is in the wrong position after a
power failure. Both MOP and MON outputs are active high.
The motor drive wave forms are shown below:
LED
t
LED
DR-01332
Signal
Output
Value
Description
SEL 1
0
1
Channel 1 selected (IIN1/IIP1)
Channel 2 selected (IIN2/IIP2)
MP1
MP0
Motor drive
output
selection
V
SS
V
SS
V
DD
V
DD
V
SS
V
DD
V
SS
V
DD
Unit
Pulse Rate
Selection Input
1
10
100
Device test mode
pulses/kWh
pulses/kWh
pulses/kWh
Signal Input RATED
Rated Conditions
V
SS
OPEN
V
DD
230V / 20A
230V / 40A
230V / 60A
LED output (LED)
The LED output pulse at a fixed rate of 6400 pulses per kWh.
The LED output is active low. The LED waveform is shown
below:
An integrated anti-creep function prevents any output pulses if
the measured power is less than 0.02% of the meters rated
current.
Selected input indicator (SEL1)
The SA2007M continuously compares the power
consumptions on current channel 1 inputs and current channel
2 inputs. The larger of the two measurements are used for
metering. The SEL1 output pin indicates which channel is
currently being used for the pulse output.
t = 142ms
m
VDD
VDD
VSS
VSS
MON
MOP
t
m
t
m
t
m
DR-01559
VDD
VSS
Switching between channels will not be faster than once per
second when both channels are balanced.
PRELIMINARY